Difference between revisions of "Bot test"

From Flowcode Help
Jump to navigationJump to search
 
(76 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
+
{| style="width:50%"
 
 
{| width="50%"
 
 
|-
 
|-
| width="20%" style="color: gray;" | Author
+
| width="20%" style="color:gray;" | Author
| Matrix TSL
+
| Matrix Ltd.
 
|-
 
|-
| width="20%" style="color: gray;" | Version
+
| width="20%" style="color:gray;" | Version
| 1.0 (Release)
+
| 2.0
 
|-
 
|-
| width="20%" style="color: gray;" | Category
+
| width="20%" style="color:gray;" | Category
| Analog Input
+
| Wireless
 
|}
 
|}
  
  
 +
==Bluetooth (EB024, Generic AT) component==
 +
Low level routines for controlling a standard AT Bluetooth interface. Also available in the form of the EB024 Bluetooth E-block.
 +
 +
==Detailed description==
  
==[[File:Component Icon 937e425e_21c0_4b08_8d8f_0bf80a6391d2.png|Image]] ADC (AD7680) component==
+
''No detailed description exists yet for this component''
16-bit external ADC connected to the microcontroller using SPI.
 
  
 
==Examples==
 
==Examples==
''<span style="color:red;">No additional examples</span>''
 
  
  
==Downloadable macro reference==
+
===Making a device discoverable===
  
===<span style="font-weight: normal;"><u><tt>SampleADC</tt></u></span>===
+
Example program to set up the Bluetooth module to be discoverable with a pair key. Any data received is then output onto the LCD component. You can connect to the Bluetooth device using a PC with Bluetooth connection and using software such as Flowcode 6, RealTerm or HyperTerminal. Alternatively you can connect using a smart phone running a terminal emulator app or via another embedded Bluetooth board.
Reads the ADC and returns the reading as an unsigned 16-bit value.
+
{{Fcfile|BluetoothDiscover.fcfx|Bluetooth Discover}}
 +
Script 1 contains the AT commands to setup the Bluetooth device to be discoverable with pair key "1234".
  
Range: 0-65535 / 0=0V / 65535=VCC
+
[[File:DiscoverableScript.jpg]]
  
'''Parameters'''
 
  
:''This macro has no parameters''
+
===Searching for a device===
  
 +
Example program to scan for local discoverable Bluetooth devices. For each device found the MAC address is displayed on to the LCD.
 +
{{Fcfile|BluetoothInquire.fcfx|Bluetooth Inquiry}}
 +
===Connecting to a device===
  
'''Return value'''
+
Example program to connect to a specific Bluetooth device address and send data to the device.
 +
{{Fcfile|BluetoothConnect.fcfx|Bluetooth Connect}}
 +
The device MAC address is specified using the "CreateCommandString" and "SendCommand" macros.
  
:[[Variable Types|UINT]]
+
[[File:ConnectToMAC.jpg]]
  
  
===<span style="font-weight: normal;"><u><tt>Initialise</tt></u></span>===
 
Initialise the SPI bus ready for communications,
 
  
'''Parameters'''
+
==Downloadable macro reference==
  
:''This macro has no parameters''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''StringRead'''
 +
|-
 +
| colspan="2" | Returns the ASCII value of character idx of the Response string.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | idx
 +
|-
 +
| colspan="2" | Needs to be a equal to or less than the string length of the response in order to retrieve a valid character.&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
'''Return value'''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SendScript'''
 +
|-
 +
| colspan="2" | Sends Script idx  Note that the general property Number of Scripts needs to be set so that it allows the scripts to be accessed and sent.  Returns 0 for success and 1 for error &nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | idx
 +
|-
 +
| colspan="2" | Refers to the Script page to send (1-4).&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:''This call does not return a value''
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SendCommand'''
 +
|-
 +
| colspan="2" | Sends the command buffer. Returns 1 for success in sending the command. Returns 0 for errors.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | ExpectEcho
 +
|-
 +
| colspan="2" | Remote module automatically echos back data: 1 = On (Expect echo), 0 = off&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | SendCR
 +
|-
 +
| colspan="2" | Automatically adds \n to the end of the command data: 1 = append CR, 0 = no CR.&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
==Simulation macro reference==
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''CreateCommandString'''
 +
|-
 +
| colspan="2" | Assigns a string of characters to the Command buffer. Returns 1 for success in adding the characters to the buffer. Returns 0 for errors, including Buffer overflow.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-string-icon.png]] - STRING
 +
| width="90%" | Data
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
''This component does not contain any simulation macros''
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''StringReceive'''
 +
|-
 +
| colspan="2" | Checks for a response string. Returns the length of the response string if one is present otherwise returns 0. &nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
==Property reference==
 
<span style="font-weight: normal;"><u>Channel</u></span>
 
  
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''cal_spi1::CHANNEL''.
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''CreateCommand'''
 +
|-
 +
| colspan="2" | Adds a single characters to the end of the Command buffer. Returns 1 for success in adding the characters to the buffer. Returns 0 for errors, including Buffer overflow.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Character
 +
|-
 +
| colspan="2" | ASCII value or single character,&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
SPI Channel selector
 
  
<span style="font-weight: normal;"><u>Prescale</u></span>
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Send_byte'''
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | ByteVal
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''cal_spi1::PR_SCALE''.
 
  
Prescale option selector
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''WaitForResponse'''
 +
|-
 +
| colspan="2" | Waits for a response message of type response_code for timeout ms. Returns: 0 for a Response of type response_code 255 (0xFF) for a timeout or invalid response Response string length for any Response not of type response_code&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | response_code
 +
|-
 +
| colspan="2" | 1:OK / 2:ERROR / 3:CONNECT / 4:NO CARRIER / 5:AUDIO / 6:PAIR / 7:RING&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | timeout
 +
|-
 +
| colspan="2" | The timeout value will need to set to allow sufficient time for the response to arrive.&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
<span style="font-weight: normal;"><u>MOSI</u></span>
 
  
This property is of type ''Single digital pin'' and can be referenced with the variable name ''cal_spi1::MOSI''.
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Initialise'''
 +
|-
 +
| colspan="2" | Required to be used whenever the Bluetooth component is used in a program. Initialises the Bluetooth component ready for use.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
SPI Data Out Pin SDO - Also Known as Master Out Slave In (MOSI) when used in Master mode.
 
  
<span style="font-weight: normal;"><u>MISO</u></span>
 
  
This property is of type ''Single digital pin'' and can be referenced with the variable name ''cal_spi1::MISO''.
 
  
SPI Data In Pin SDI - Also Known as Master In Slave Out (MISO) when used in Master mode.
+
==Property reference==
  
<span style="font-weight: normal;"><u>CLK</u></span>
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
+
|-
This property is of type ''Single digital pin'' and can be referenced with the variable name ''cal_spi1::CLK''.
+
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-prop-icon.png]]
 
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Properties'''  
SPI Clock Pin CLK - The Clock signal is driven by the SPI master.
+
|-
 
+
|-
<span style="font-weight: normal;"><u>CS / SS</u></span>
+
| width="10%" align="center" | [[File:Fc9-type-21-icon.png]]
 
+
| width="90%" | Command Buffer Size
This property is of type ''Single digital pin'' and can be referenced with the variable name ''cal_spi1::SS''.
+
|-
 
+
| colspan="2" | Maximum number of bytes that can be stored in the outgoing command buffer.&nbsp;
Chip Select / Slave Select Pin  
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-21-icon.png]]
Master Mode: General purpose output pin used to select the remote SPI device.
+
| width="90%" | Response Buffer Size
 
+
|-
Slave Mode: Hardware chip select pin input used to select the SPI device.
+
| colspan="2" | Maximum number of bytes that can be stored in the incoming response buffer.&nbsp;
 
+
|-
<span style="font-weight: normal;"><u>Simulate Comms</u></span>
+
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 
+
| width="90%" | Script Count
This property is of type ''True or false'' and can be referenced with the variable name ''SimulateComms''.
+
|-
 
+
| colspan="2" | Controls how many AT scripts are stored into non-volatile memory&nbsp;
''<span style="color:red;">No additional information</span>''
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-11-icon.png]]
 
+
| width="90%" | Script 1
 
+
|-
<span style="font-weight: normal;"><u>Console Data</u></span>
+
| colspan="2" | Data to send for script 0, each command should be terminated with a carriage return&nbsp;
 
+
|-
This property is of type ''True or false'' and can be referenced with the variable name ''cal_spi1::ConsoleData''.
+
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-conn-icon.png]]
 
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Connections'''  
Selects if the console data is automatically generated or not
+
|-
 
+
|-
<span style="font-weight: normal;"><u>Scope Traces</u></span>
+
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 
+
| width="90%" | Channel
This property is of type ''True or false'' and can be referenced with the variable name ''cal_spi1::ScopeTraces''.
+
|-
 
+
| colspan="2" | UART Channel selector Software channels are bit banged using generic I/O pins but are not as reliable as hardware channels. Hardware channels use the selected peripheral on-board the target microcontroller.&nbsp;
Selects if the scope traces are automatically generated or not
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-5-icon.png]]
<span style="font-weight: normal;"><u>Injector</u></span>
+
| width="90%" | TX
 
+
|-
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''cal_spi1::Injector''.
+
| colspan="2" | Pin to be used for Transmit data&nbsp;
 
+
|-
''<span style="color:red;">No additional information</span>''
+
| width="10%" align="center" | [[File:Fc9-type-5-icon.png]]
 +
| width="90%" | RX
 +
|-
 +
| colspan="2" | Pin to be used for Receive data&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 +
| width="90%" | Use Flow Control
 +
|-
 +
| colspan="2" | Flow Control (Handshake) enable or disable.    On: Two I/O pins are used to control the flow of data in and out of the device.     Off: Flow control is disabled.&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 +
| width="90%" | Baud Options
 +
|-
 +
| colspan="2" | Baud rate option selector&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-14-icon.png]]
 +
| width="90%" | Baud Rate
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-conn-icon.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Simulations'''  
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-21-icon.png]]
 +
| width="90%" | Console Columns
 +
|-
 +
| colspan="2" | Number of characters that can be displayed on a single line of the console.&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-7-icon.png]]
 +
| width="90%" | Console Data
 +
|-
 +
| colspan="2" | Selects if the console data is automatically generated or not&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-7-icon.png]]
 +
| width="90%" | Scope Traces
 +
|-
 +
| colspan="2" | Selects if the scope traces are automatically added to the data recorder window or not.    Simulation - draws an approximation of the UART data onto the scope trace.    ICT - sets up the scope trace for incoming data and adds UART packet decoding at the correct BAUD.&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 +
| width="90%" | Data Source
 +
|-
 +
| colspan="2" | Simulation data source used to allow the component to connect to various remote devices    Nothing - Simulation data is ignored    COM port - Routes the communication data to and from a physical or virtual COM port      API - Routes the communication data via a data API component on the Panel.&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
 +
| width="90%" | API
 +
|-
 +
| colspan="2" | Selects whichAPI component to route the communication data via. Add API components to the panel before they will be available in this list. API components are available from the Comms component category.&nbsp;
 +
|}

Latest revision as of 13:33, 31 August 2021

Author Matrix Ltd.
Version 2.0
Category Wireless


Bluetooth (EB024, Generic AT) component

Low level routines for controlling a standard AT Bluetooth interface. Also available in the form of the EB024 Bluetooth E-block.

Detailed description

No detailed description exists yet for this component

Examples

Making a device discoverable

Example program to set up the Bluetooth module to be discoverable with a pair key. Any data received is then output onto the LCD component. You can connect to the Bluetooth device using a PC with Bluetooth connection and using software such as Flowcode 6, RealTerm or HyperTerminal. Alternatively you can connect using a smart phone running a terminal emulator app or via another embedded Bluetooth board. FC6 Icon.png Bluetooth Discover Script 1 contains the AT commands to setup the Bluetooth device to be discoverable with pair key "1234".

DiscoverableScript.jpg


Searching for a device

Example program to scan for local discoverable Bluetooth devices. For each device found the MAC address is displayed on to the LCD. FC6 Icon.png Bluetooth Inquiry

Connecting to a device

Example program to connect to a specific Bluetooth device address and send data to the device. FC6 Icon.png Bluetooth Connect The device MAC address is specified using the "CreateCommandString" and "SendCommand" macros.

ConnectToMAC.jpg


Downloadable macro reference

Fc9-comp-macro.png StringRead
Returns the ASCII value of character idx of the Response string. 
Fc9-u8-icon.png - BYTE idx
Needs to be a equal to or less than the string length of the response in order to retrieve a valid character. 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png SendScript
Sends Script idx Note that the general property Number of Scripts needs to be set so that it allows the scripts to be accessed and sent. Returns 0 for success and 1 for error  
Fc9-u8-icon.png - BYTE idx
Refers to the Script page to send (1-4). 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png SendCommand
Sends the command buffer. Returns 1 for success in sending the command. Returns 0 for errors. 
Fc9-u8-icon.png - BYTE ExpectEcho
Remote module automatically echos back data: 1 = On (Expect echo), 0 = off 
Fc9-u8-icon.png - BYTE SendCR
Automatically adds \n to the end of the command data: 1 = append CR, 0 = no CR. 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png CreateCommandString
Assigns a string of characters to the Command buffer. Returns 1 for success in adding the characters to the buffer. Returns 0 for errors, including Buffer overflow. 
Fc9-string-icon.png - STRING Data
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png StringReceive
Checks for a response string. Returns the length of the response string if one is present otherwise returns 0.  
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png CreateCommand
Adds a single characters to the end of the Command buffer. Returns 1 for success in adding the characters to the buffer. Returns 0 for errors, including Buffer overflow. 
Fc9-u8-icon.png - BYTE Character
ASCII value or single character, 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png Send_byte
 
Fc9-u8-icon.png - BYTE ByteVal
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png WaitForResponse
Waits for a response message of type response_code for timeout ms. Returns: 0 for a Response of type response_code 255 (0xFF) for a timeout or invalid response Response string length for any Response not of type response_code 
Fc9-u8-icon.png - BYTE response_code
1:OK / 2:ERROR / 3:CONNECT / 4:NO CARRIER / 5:AUDIO / 6:PAIR / 7:RING 
Fc9-u8-icon.png - BYTE timeout
The timeout value will need to set to allow sufficient time for the response to arrive. 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png Initialise
Required to be used whenever the Bluetooth component is used in a program. Initialises the Bluetooth component ready for use. 
Fc9-void-icon.png - VOID Return



Property reference

Fc9-prop-icon.png Properties
Fc9-type-21-icon.png Command Buffer Size
Maximum number of bytes that can be stored in the outgoing command buffer. 
Fc9-type-21-icon.png Response Buffer Size
Maximum number of bytes that can be stored in the incoming response buffer. 
Fc9-type-16-icon.png Script Count
Controls how many AT scripts are stored into non-volatile memory 
Fc9-type-11-icon.png Script 1
Data to send for script 0, each command should be terminated with a carriage return 
Fc9-conn-icon.png Connections
Fc9-type-16-icon.png Channel
UART Channel selector Software channels are bit banged using generic I/O pins but are not as reliable as hardware channels. Hardware channels use the selected peripheral on-board the target microcontroller. 
Fc9-type-5-icon.png TX
Pin to be used for Transmit data 
Fc9-type-5-icon.png RX
Pin to be used for Receive data 
Fc9-type-16-icon.png Use Flow Control
Flow Control (Handshake) enable or disable. On: Two I/O pins are used to control the flow of data in and out of the device. Off: Flow control is disabled. 
Fc9-type-16-icon.png Baud Options
Baud rate option selector 
Fc9-type-14-icon.png Baud Rate
 
Fc9-conn-icon.png Simulations
Fc9-type-21-icon.png Console Columns
Number of characters that can be displayed on a single line of the console. 
Fc9-type-7-icon.png Console Data
Selects if the console data is automatically generated or not 
Fc9-type-7-icon.png Scope Traces
Selects if the scope traces are automatically added to the data recorder window or not. Simulation - draws an approximation of the UART data onto the scope trace. ICT - sets up the scope trace for incoming data and adds UART packet decoding at the correct BAUD. 
Fc9-type-16-icon.png Data Source
Simulation data source used to allow the component to connect to various remote devices Nothing - Simulation data is ignored COM port - Routes the communication data to and from a physical or virtual COM port API - Routes the communication data via a data API component on the Panel. 
Fc9-type-16-icon.png API
Selects whichAPI component to route the communication data via. Add API components to the panel before they will be available in this list. API components are available from the Comms component category.