Difference between revisions of "Component: RC5 (EB060, Generic 36KHz) (Wireless)"

From Flowcode Help
Jump to navigationJump to search
Line 1: Line 1:
 
+
{| style="width:50%"
 
 
{| width="50%"
 
 
|-
 
|-
| width="20%" style="color: gray;" | Author
+
| width="20%" style="color:gray;" | Author
 
| Matrix Ltd.
 
| Matrix Ltd.
 
|-
 
|-
| width="20%" style="color: gray;" | Version
+
| width="20%" style="color:gray;" | Version
| 1.2 (Release)
+
| 1.2
 
|-
 
|-
| width="20%" style="color: gray;" | Category
+
| width="20%" style="color:gray;" | Category
 
| Wireless
 
| Wireless
 
|}
 
|}
  
  
 +
==RC5 (EB060, Generic 36KHz) component==
 +
Low level routines for controlling a standard RC5 IR interface. Also available in the form of the EB060 RC5 E-block.
 +
 +
==Detailed description==
  
==[[File:Component Icon 81e90a9f_1594_4b34_8aef_5dd671dddc30.png|Image]] RC5 (EB060, Generic 36KHz) component==
+
''No detailed description exists yet for this component''
Low level routines for controlling a standard RC5 IR interface.
 
Also available in the form of the EB060 RC5 E-block.
 
  
 
==Examples==
 
==Examples==
 +
 +
 
===Receive Data===
 
===Receive Data===
  
Line 35: Line 37:
 
==Downloadable macro reference==
 
==Downloadable macro reference==
  
===<span style="font-weight: normal;"><u><tt>CollectData</tt></u></span>===
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
Retreives a value from the last successful RC5 reception.
+
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''CollectData'''
 +
|-
 +
| colspan="2" | Retreives a value from the last successful RC5 reception. 0 = Read Command 1 = Read Address 2 = Read Toggle Bit&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | selection
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
0 = Read Command
 
  
1 = Read Address
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''RXDisable'''
 +
|-
 +
| colspan="2" | Disables the RC5 data receive functionality.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
2 = Read Toggle Bit
 
  
'''Parameters'''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''TXPacket'''
 +
|-
 +
| colspan="2" | Transmits a RC5 data packet consisting of command, address and toggle bit.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | command
 +
|-
 +
| colspan="2" | Command to send 0-63&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | address
 +
|-
 +
| colspan="2" | Address to send 0-31&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | toggle
 +
|-
 +
| colspan="2" | Toggle bit value 0-1&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:[[Variable Types|BYTE]] ''selection''
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''TXEnable'''
 +
|-
 +
| colspan="2" | Enables the RC5 data transmit functionality.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
'''Return value'''
 
  
:[[Variable Types|BYTE]]
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''CheckRx'''
 +
|-
 +
| colspan="2" | Checks to see if a new RC5 packet has been received. Returns 0 to signify no new data available. Returns 1 to signify there is new data available.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
===<span style="font-weight: normal;"><u><tt>RXDisable</tt></u></span>===
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
Disables the RC5 data receive functionality.
+
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''TXDisable'''
 +
|-
 +
| colspan="2" | Disables the RC5 data transmit functionality.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
'''Parameters'''
 
  
:''This macro has no parameters''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''RXEnable'''
 +
|-
 +
| colspan="2" | Enables the RC5 data receive functionality.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
'''Return value'''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''CommsBaud'''
 +
|-
 +
| colspan="2" | Sets the Baud rate of the alt communications channel&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Baud
 +
|-
 +
| colspan="2" | Range: 0-7 : 0=1200 / 7=115200&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:''This call does not return a value''
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDOptions'''
 +
|-
 +
| colspan="2" | Controls some of the LCD options&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Foreground
 +
|-
 +
| colspan="2" | Range: 0-1&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Background
 +
|-
 +
| colspan="2" | Range: 0-1&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Transparent
 +
|-
 +
| colspan="2" | Range: 0-1&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
===<span style="font-weight: normal;"><u><tt>TXPacket</tt></u></span>===
 
Transmits a RC5 data packet consisting of command, address and toggle bit.
 
  
'''Parameters'''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDVerbose'''
 +
|-
 +
| colspan="2" | Controls the Verbose mode.  When enabled the LCD automatically displays an account of the incoming API commands and parameters. When switched off the LCD is free for the user to control as required.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Mode
 +
|-
 +
| colspan="2" | Range: 0-1 : 0=Off or User Mode / 1=API Verbose Mode&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:[[Variable Types|BYTE]] ''command''
 
::Command to send 0-63
 
  
:[[Variable Types|BYTE]] ''address''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
::Address to send 0-31
+
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadDigitalInput'''
 +
|-
 +
| colspan="2" | Reads a single digital input.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Channel
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:[[Variable Types|BYTE]] ''toggle''
 
::Toggle bit value 0-1
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''PWMConfig'''
 +
|-
 +
| colspan="2" | Sets the PWM configuration. Channel = 0 - 1 : 0 = EN_AB, A, B / 1 = EN_CD, C, D Period = 0 - 65535 Scaler = 0 - 3 :  0=1:1 1=1:8 2=1:64 3=1:256&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Channel
 +
|-
 +
| colspan="2" | Range 0-1&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT
 +
| width="90%" | Period
 +
|-
 +
| colspan="2" | Range: 0-65535&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Scaler
 +
|-
 +
| colspan="2" | Range: 0-3&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
'''Return value'''
 
  
:''This call does not return a value''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''PWMEnable'''
 +
|-
 +
| colspan="2" | Allows pulse width modulated transistor outputs to be switched on or off. Bit 0 = Enable AB Bit 1 = A / Bit 2 = B Bit 3 = C / Bit 4 = D Bit 5 = Enable CD&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | EnableMask
 +
|-
 +
| colspan="2" | Range 0-63 or 0b00000 to 0b111111&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
===<span style="font-weight: normal;"><u><tt>TXEnable</tt></u></span>===
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
Enables the RC5 data transmit functionality.
+
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''PWMDuty'''
 +
|-
 +
| colspan="2" | Sets a single PWM channel duty. Channel = 0 - 5 : 0=EN_AB, 1=A, 2=B, 3=C, 4=D, 5=EN_CD Duty = 0 - 65535&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Channel
 +
|-
 +
| colspan="2" | Range 0-5&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT
 +
| width="90%" | Duty
 +
|-
 +
| colspan="2" | &nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
'''Parameters'''
 
  
:''This macro has no parameters''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDCursor'''
 +
|-
 +
| colspan="2" | Sets the cursor position for the MIAC display&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | X
 +
|-
 +
| colspan="2" | Range: 0-21&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Y
 +
|-
 +
| colspan="2" | Range: 0-4&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
  
'''Return value'''
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''WriteTran'''
 +
|-
 +
| colspan="2" | Allows a single transistor output to be switched on or off.&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Channel
 +
|-
 +
| colspan="2" | Range 1-4&nbsp;
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Value
 +
|-
 +
| colspan="2" | 0 = Off, 1 = On&nbsp;
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
:''This call does not return a value''
 
  
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDClear'''
 +
|-
 +
| colspan="2" | Clears the MIAC display&nbsp;
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
  
===<span style="font-weight: normal;"><u><tt>CheckRx</tt></u></span>===
 
Checks to see if a new RC5 packet has been received.
 
 
Returns 0 to signify no new data available.
 
 
Returns 1 to signify there is new data available.
 
 
'''Parameters'''
 
 
:''This macro has no parameters''
 
 
 
'''Return value'''
 
 
:[[Variable Types|BYTE]]
 
 
 
===<span style="font-weight: normal;"><u><tt>TXDisable</tt></u></span>===
 
Disables the RC5 data transmit functionality.
 
 
'''Parameters'''
 
 
:''This macro has no parameters''
 
 
 
'''Return value'''
 
 
:''This call does not return a value''
 
  
 
===<span style="font-weight: normal;"><u><tt>RXEnable</tt></u></span>===
 
Enables the RC5 data receive functionality.
 
 
'''Parameters'''
 
 
:''This macro has no parameters''
 
 
 
'''Return value'''
 
 
:''This call does not return a value''
 
 
 
 
==Simulation macro reference==
 
 
''This component does not contain any simulation macros''
 
  
  
 
==Property reference==
 
==Property reference==
<span style="font-weight: normal;"><u>IR Frequency</u></span>
 
  
This property is of type ''Unsigned integer'' and can be referenced with the variable name ''ir_freq''.
+
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
+
|-
The infra-red modulation frequency used when transmitting a logic one.
+
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-prop-icon.png]]
 
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Properties'''  
<span style="font-weight: normal;"><u>Receive Mode</u></span>
+
|-
 
+
|-
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''rx_mode''.
+
| width="10%" align="center" | [[File:Fc9-type-21-icon.png]]
 
+
| width="90%" | IR Frequency
Specifies which receive mode the program should use.
+
|-
 
+
| colspan="2" | The infra-red modulation frequency used when transmitting a logic one.&nbsp;
<span style="font-weight: normal;"><u>Invert Signal</u></span>
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
This property is of type ''True or false'' and can be referenced with the variable name ''rx_invert_signal''.
+
| width="90%" | Receive Mode
 
+
|-
Allows the incoming signal to automatically be inverted if needed by the receive hardware.
+
| colspan="2" | Specifies which receive mode the program should use.&nbsp;
 
+
|-
<span style="font-weight: normal;"><u>Address Mask</u></span>
+
| width="10%" align="center" | [[File:Fc9-type-7-icon.png]]
 
+
| width="90%" | Invert Signal
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''rx_addr_mask''.
+
|-
 
+
| colspan="2" | Allows the incoming signal to automatically be inverted if needed by the receive hardware.&nbsp;
What incoming values should we allow to make it through to the CheckRx macro.
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
<span style="font-weight: normal;"><u>Receive Pin</u></span>
+
| width="90%" | Address Mask
 
+
|-
This property is of type ''Single digital pin'' and can be referenced with the variable name ''rx_pin''.
+
| colspan="2" | What incoming values should we allow to make it through to the CheckRx macro.&nbsp;
 
+
|-
Pin assigned to receive incoming RC5 data
+
| width="10%" align="center" | [[File:Fc9-type-5-icon.png]]
 
+
| width="90%" | Receive Pin
<span style="font-weight: normal;"><u>Transmit Mode</u></span>
+
|-
 
+
| colspan="2" | Pin assigned to receive incoming RC5 data&nbsp;
This property is of type ''Fixed list of ints'' and can be referenced with the variable name ''tx_mode''.
+
|-
 
+
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]]
Specifies which transmit mode the program should use.
+
| width="90%" | Transmit Mode
 
+
|-
<span style="font-weight: normal;"><u>Label</u></span>
+
| colspan="2" | Specifies which transmit mode the program should use.&nbsp;
 
+
|-
This property is of type ''Line of text'' and can be referenced with the variable name ''label''.
+
| width="10%" align="center" | [[File:Fc9-type-10-icon.png]]
 
+
| width="90%" | Label
Label used to help identify the component on the panel.
+
|-
 +
| colspan="2" | Label used to help identify the component on the panel.&nbsp;
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-conn-icon.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Connections'''  
 +
|-
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-conn-icon.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Simulations'''  
 +
|-
 +
|}

Revision as of 20:35, 16 November 2021

Author Matrix Ltd.
Version 1.2
Category Wireless


RC5 (EB060, Generic 36KHz) component

Low level routines for controlling a standard RC5 IR interface. Also available in the form of the EB060 RC5 E-block.

Detailed description

No detailed description exists yet for this component

Examples

Receive Data

Example to receive data via RC5 encoded IR. RC5 incoming data pin connected to pin RB0. If a valid RC5 packet is received then the 8-bit data is shown on the PORTD pins and the 5-bit address data is shown on the PORTA pins. FC6 Icon.png RC5 Receive Example

Transmit Data

Example to send data via RC5 encoded IR. The transmission is done via the RC0 pin and the modulation is performed by the PWM output signal on the RC2 pin. The data and address values are incremented after each transmission. FC6 Icon.png RC5 Transmit Example

Schematic showing the required hardware to combine TX masking pin and PWM output pin.

RC5 TX.jpg

Downloadable macro reference

Fc9-comp-macro.png CollectData
Retreives a value from the last successful RC5 reception. 0 = Read Command 1 = Read Address 2 = Read Toggle Bit 
Fc9-u8-icon.png - BYTE selection
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png RXDisable
Disables the RC5 data receive functionality. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png TXPacket
Transmits a RC5 data packet consisting of command, address and toggle bit. 
Fc9-u8-icon.png - BYTE command
Command to send 0-63 
Fc9-u8-icon.png - BYTE address
Address to send 0-31 
Fc9-u8-icon.png - BYTE toggle
Toggle bit value 0-1 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png TXEnable
Enables the RC5 data transmit functionality. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png CheckRx
Checks to see if a new RC5 packet has been received. Returns 0 to signify no new data available. Returns 1 to signify there is new data available. 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png TXDisable
Disables the RC5 data transmit functionality. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png RXEnable
Enables the RC5 data receive functionality. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png CommsBaud
Sets the Baud rate of the alt communications channel 
Fc9-u8-icon.png - BYTE Baud
Range: 0-7 : 0=1200 / 7=115200 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDOptions
Controls some of the LCD options 
Fc9-u8-icon.png - BYTE Foreground
Range: 0-1 
Fc9-u8-icon.png - BYTE Background
Range: 0-1 
Fc9-u8-icon.png - BYTE Transparent
Range: 0-1 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDVerbose
Controls the Verbose mode. When enabled the LCD automatically displays an account of the incoming API commands and parameters. When switched off the LCD is free for the user to control as required. 
Fc9-u8-icon.png - BYTE Mode
Range: 0-1 : 0=Off or User Mode / 1=API Verbose Mode 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png ReadDigitalInput
Reads a single digital input. 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png PWMConfig
Sets the PWM configuration. Channel = 0 - 1 : 0 = EN_AB, A, B / 1 = EN_CD, C, D Period = 0 - 65535 Scaler = 0 - 3 : 0=1:1 1=1:8 2=1:64 3=1:256 
Fc9-u8-icon.png - BYTE Channel
Range 0-1 
Fc9-u16-icon.png - UINT Period
Range: 0-65535 
Fc9-u8-icon.png - BYTE Scaler
Range: 0-3 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png PWMEnable
Allows pulse width modulated transistor outputs to be switched on or off. Bit 0 = Enable AB Bit 1 = A / Bit 2 = B Bit 3 = C / Bit 4 = D Bit 5 = Enable CD 
Fc9-u8-icon.png - BYTE EnableMask
Range 0-63 or 0b00000 to 0b111111 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png PWMDuty
Sets a single PWM channel duty. Channel = 0 - 5 : 0=EN_AB, 1=A, 2=B, 3=C, 4=D, 5=EN_CD Duty = 0 - 65535 
Fc9-u8-icon.png - BYTE Channel
Range 0-5 
Fc9-u16-icon.png - UINT Duty
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDCursor
Sets the cursor position for the MIAC display 
Fc9-u8-icon.png - BYTE X
Range: 0-21 
Fc9-u8-icon.png - BYTE Y
Range: 0-4 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png WriteTran
Allows a single transistor output to be switched on or off. 
Fc9-u8-icon.png - BYTE Channel
Range 1-4 
Fc9-u8-icon.png - BYTE Value
0 = Off, 1 = On 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDClear
Clears the MIAC display 
Fc9-void-icon.png - VOID Return



Property reference

Fc9-prop-icon.png Properties
Fc9-type-21-icon.png IR Frequency
The infra-red modulation frequency used when transmitting a logic one. 
Fc9-type-16-icon.png Receive Mode
Specifies which receive mode the program should use. 
Fc9-type-7-icon.png Invert Signal
Allows the incoming signal to automatically be inverted if needed by the receive hardware. 
Fc9-type-16-icon.png Address Mask
What incoming values should we allow to make it through to the CheckRx macro. 
Fc9-type-5-icon.png Receive Pin
Pin assigned to receive incoming RC5 data 
Fc9-type-16-icon.png Transmit Mode
Specifies which transmit mode the program should use. 
Fc9-type-10-icon.png Label
Label used to help identify the component on the panel. 
Fc9-conn-icon.png Connections
Fc9-conn-icon.png Simulations