Difference between revisions of "Component: RadioButton (Controls )"

From Flowcode Help
Jump to navigationJump to search
(Created page with "{| style="width:50%" |- | width="20%" style="color:gray;" | Author | Matrix TSL |- | width="20%" style="color:gray;" | Version | 1.0 |- | width="20%" style="color:gray...")
 
Line 16: Line 16:
  
 
==Detailed description==
 
==Detailed description==
 +
 +
  
 
''No detailed description exists yet for this component''
 
''No detailed description exists yet for this component''
  
 
==Examples==
 
==Examples==
 +
 +
  
  
Line 233: Line 237:
 
|-
 
|-
 
| colspan="2" | Initialise the comms to the Arduino board ready for commands to be sent. 
 
| colspan="2" | Initialise the comms to the Arduino board ready for commands to be sent. 
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
 +
 +
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadAnalogInput'''
 +
|-
 +
| colspan="2" | Reads a single digital input. 
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | Channel
 +
|-
 +
| colspan="2" |  
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
 +
 +
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''PWMEnable'''
 +
|-
 +
| colspan="2" | Allows pulse width modulated transistor outputs to be switched on or off. Bit 0 = Enable AB Bit 1 = A / Bit 2 = B Bit 3 = C / Bit 4 = D Bit 5 = Enable CD 
 +
|-
 +
|-
 +
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
 +
| width="90%" | EnableMask
 +
|-
 +
| colspan="2" | Range 0-63 or 0b00000 to 0b111111 
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
 +
 +
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Initialise'''
 +
|-
 +
| colspan="2" |  
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
 +
 +
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDClear'''
 +
|-
 +
| colspan="2" | Clears the MIAC display 
 +
|-
 +
|-
 +
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 +
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 +
|}
 +
 +
 +
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 +
|-
 +
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 +
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''LCDClear'''
 +
|-
 +
| colspan="2" | Clears the LCD 
 
|-
 
|-
 
|-
 
|-

Revision as of 10:38, 17 November 2021

Author Matrix TSL
Version 1.0
Category Controls


RadioButton component

A simple radio button component allowing an array of up to 20 on/off type settings.

Detailed description

No detailed description exists yet for this component

Examples

Industrial Tanks

A simple example showing the hoppers, valves and pipes working together. Each tank automatically empties in turn.

FC6 Icon.png Industrial Tanks

Downloadable macro reference

Fc9-comp-macro.png GetIndex
Gets the current selected index. Returns 1 - NumberOptions 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png Prv_DisplaySelectedItem
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png SetIndex
Sets the selected item. 
Fc9-u8-icon.png - BYTE Index
Range: 1 - Number Options 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png ClearBuffer
Erases the contents of the buffer 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png ReadDigitalInputs
Reads the state of up to eight digital inputs. Can pack a max of 8-bits together in a single operation 
Fc9-u16-icon.png - UINT StartAddress
Coil Address Range 0 to (NumCoils - 1) 
Fc9-u8-icon.png - BYTE AddressCount
Range 1-8 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png GetLastIncoming
Gets a value from the last incoming command. Index 0 = 0 Read / 1 Write Index 1 = 0 Coils / 1 DigInput / 2 AnInput / 3 Register Index 2 = Address Index 3 = Number 
Fc9-u16-icon.png - UINT Return


Fc9-comp-macro.png SetAnalogInput
Sets the state of a single analogue input. 
Fc9-u16-icon.png - UINT Address
Coil Address 
Fc9-u16-icon.png - UINT Value
Analogue Value range 0 - 65535 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Initialise
Starts up the UART to allow communications and initialises the states of the various Modbus Coils, Inputs and Registers to 0. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png AppendStringToFile
Adds the contents of the data string parameter to the end of the currently open file. Returns 0 for success. 
Fc9-string-icon.png - STRING Data_String
Data to append to the end of the file 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png ReadFileSize
Reads the entire size of the current file in bytes. 
Fc9-u32-icon.png - ULONG Return


Fc9-comp-macro.png SetTimeAndDate
Sets the current time and date. Time = (Hour << 11) + (Min << 5) + (Sec >> 1) Date = (YearFrom1980 << 9) + (Month << 5) + (Day) Additional details can be found here: http://www.maverick-os.dk/FileSystemFormats/FAT16_FileSystem.html#TimeFormat 
Fc9-u16-icon.png - UINT Time
Sets the current Time in FAT Time format hhhhhmmmmmmsssss - S=Secs/2 
Fc9-u16-icon.png - UINT Date
Sets the current Date in FAT Date format yyyyyyymmmmddddd - Y=Years since 1980 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Initialise
Attempts to communicate with the SD card and if successful sets up the file system. Returns 0 for success.  
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png Initialise
Initialise the comms to the Arduino board ready for commands to be sent. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png ReadAnalogInput
Reads a single digital input. 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u16-icon.png - UINT Return


Fc9-comp-macro.png PWMEnable
Allows pulse width modulated transistor outputs to be switched on or off. Bit 0 = Enable AB Bit 1 = A / Bit 2 = B Bit 3 = C / Bit 4 = D Bit 5 = Enable CD 
Fc9-u8-icon.png - BYTE EnableMask
Range 0-63 or 0b00000 to 0b111111 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Initialise
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDClear
Clears the MIAC display 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png LCDClear
Clears the LCD 
Fc9-void-icon.png - VOID Return



Property reference

Fc9-prop-icon.png Properties
Fc9-type-16-icon.png Number Options
 
Fc9-type-16-icon.png Initial Value
 
Fc9-type-11-icon.png Text1
 
Fc9-type-11-icon.png Text2
 
Fc9-type-11-icon.png Text3
 
Fc9-type-12-icon.png Style
 
Fc9-type-1-icon.png Colour
 
Fc9-type-7-icon.png Show Label
 
Fc9-type-1-icon.png Text Colour
 
Fc9-type-15-icon.png Text Scale
 
Fc9-type-15-icon.png Spacing
Space between radio button items 
Fc9-type-15-icon.png Text Spacing
Space between text and radio button item. 
Fc9-conn-icon.png Connections
Fc9-conn-icon.png Simulations