Difference between revisions of "Component: Temperature Infrared (Grove 101020062) (Environmental)"
From Flowcode Help
Jump to navigationJump to search (XML import) |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | {| style="width:50%" | |
− | |||
− | {| | ||
|- | |- | ||
− | | width="20%" style="color: gray;" | Author | + | | width="20%" style="color:gray;" | Author |
| Matrix TSL | | Matrix TSL | ||
|- | |- | ||
− | | width="20%" style="color: gray;" | Version | + | | width="20%" style="color:gray;" | Version |
− | | 1.2 | + | | 1.2 |
|- | |- | ||
− | | width="20%" style="color: gray;" | Category | + | | width="20%" style="color:gray;" | Category |
| Environmental | | Environmental | ||
|} | |} | ||
+ | ==Temperature Infrared component== | ||
+ | The Grove Infrared Temperature Sensor allows none contact measurement of temperatures ranging from -10 to 100 degrees C. | ||
− | == | + | ==Component Pack== |
− | |||
− | |||
− | + | SENSORS | |
− | |||
+ | ==Detailed description== | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | ''No detailed description exists yet for this component'' | |
+ | ==Examples== | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | ''<span style="color:red;">No additional examples</span>'' | |
− | |||
− | + | ==Downloadable macro reference== | |
− | + | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |
+ | |- | ||
+ | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
+ | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''MeasureSurTemp''' | ||
+ | |- | ||
+ | | colspan="2" | Measures the surrounding ambient temperature, | ||
+ | |- | ||
+ | |- | ||
+ | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-f32-icon.png]] - FLOAT | ||
+ | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
+ | |} | ||
− | |||
− | + | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |
+ | |- | ||
+ | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
+ | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''MeasureObjectTemp''' | ||
+ | |- | ||
+ | | colspan="2" | Measures the temperature of the targetted object | ||
+ | |- | ||
+ | |- | ||
+ | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-f32-icon.png]] - FLOAT | ||
+ | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
+ | |} | ||
− | |||
− | |||
− | |||
− | + | ==Property reference== | |
− | VDD - Defines the microcontrollers power supply pin as the max reference, | + | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" |
− | + | |- | |
− | VREF+ Pin - Dedicated pin on the microcontroller to allow for a variable reference voltage. | + | | width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-prop-icon.png]] |
− | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Properties''' | |
− | + | |- | |
− | + | |- | |
− | + | | width="10%" align="center" | [[File:Fc9-type-6-icon.png]] | |
− | + | | width="90%" | Ambient Pin (SUR) | |
− | Clock setting to select how fast the ADC peripheral will perform an ADC conversion. | + | |- |
− | + | | colspan="2" | Analogue input channel - which pin is the analogue input conected to? | |
− | The FRC setting is based on a RC time base and so will vary with temperature and pressure. | + | |- |
− | + | | width="10%" align="center" | [[File:Fc9-type-6-icon.png]] | |
− | Other settings are generally based on divisions of the master clock. | + | | width="90%" | Object Pin (OBJ) |
− | + | |- | |
− | + | | colspan="2" | Analogue input channel - which pin is the analogue input conected to? | |
− | + | |- | |
− | + | | width="10%" align="center" style="background-color:#EAE1EA;" | [[File:Fc9-conn-icon.png]] | |
− | + | | width="90%" style="background-color:#EAE1EA; color:#4B008D;" | ADC Properties | |
− | Number of micro seconds to wait for the ACD input to charge before starting the analogue sample. | + | |- |
− | + | |- | |
− | + | | width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |
− | + | | width="90%" | VRef voltage | |
− | + | |- | |
− | + | | colspan="2" | Used by the GetVoltage or GetString component macros to take an ADC reading and convert it into a Voltage. +VRef voltage x 10mV Default 500 = 5.0V | |
− | Ambient temperature calibration value | + | |- |
− | + | | width="10%" align="center" | [[File:Fc9-type-16-icon.png]] | |
− | + | | width="90%" | VRef option | |
− | + | |- | |
− | + | | colspan="2" | Defines what is used as the ADC maximum reference. ADC Range = GND to VRef Voltage. VDD - Defines the microcontrollers power supply pin as the max reference, VREF+ Pin - Dedicated pin on the microcontroller to allow for a variable reference voltage. | |
− | + | |- | |
− | Map of temperature-voltage according to sensor datasheet. | + | | width="10%" align="center" | [[File:Fc9-type-16-icon.png]] |
− | + | | width="90%" | Conversion speed | |
− | 10 is the temperature step when sensor and object distance is 9CM. | + | |- |
− | + | | colspan="2" | Clock setting to select how fast the ADC peripheral will perform an ADC conversion. The FRC setting is based on a RC time base and so will vary with temperature and pressure. Other settings are generally based on divisions of the master clock. | |
− | + | |- | |
− | + | | width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |
− | + | | width="90%" | Acquisition cycles | |
− | + | |- | |
− | Voltage of mid level voltage after 5-10 mins to bring the sensor to ambient. | + | | colspan="2" | Number of micro seconds to wait for the ACD input to charge before starting the analogue sample. |
− | + | |- | |
− | + | | width="10%" align="center" style="background-color:#EAE1EA;" | [[File:Fc9-conn-icon.png]] | |
− | + | | width="90%" style="background-color:#EAE1EA; color:#4B008D;" | Advanced Settings | |
− | + | |- | |
− | + | |- | |
− | Number of samples to take to average out each reading. | + | | width="10%" align="center" | [[File:Fc9-type-15-icon.png]] |
− | + | | width="90%" | Temperature Calibration | |
− | Default 10. | + | |- |
+ | | colspan="2" | Ambient temperature calibration value | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | ||
+ | | width="90%" | Temperature Range | ||
+ | |- | ||
+ | | colspan="2" | Map of temperature-voltage according to sensor datasheet. 10 is the temperature step when sensor and object distance is 9CM. | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | ||
+ | | width="90%" | Offset Voltage | ||
+ | |- | ||
+ | | colspan="2" | Voltage of mid level voltage after 5-10 mins to bring the sensor to ambient. | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-type-21-icon.png]] | ||
+ | | width="90%" | Number of Samples | ||
+ | |- | ||
+ | | colspan="2" | Number of samples to take to average out each reading. Default 10. | ||
+ | |} |
Latest revision as of 17:23, 9 November 2022
Author | Matrix TSL |
Version | 1.2 |
Category | Environmental |
Contents
Temperature Infrared component
The Grove Infrared Temperature Sensor allows none contact measurement of temperatures ranging from -10 to 100 degrees C.
Component Pack
SENSORS
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Downloadable macro reference
![]() |
MeasureSurTemp |
Measures the surrounding ambient temperature, | |
![]() |
Return |
![]() |
MeasureObjectTemp |
Measures the temperature of the targetted object | |
![]() |
Return |