Difference between revisions of "Component: Data Transfer (API I2C) ()"
From Flowcode Help
Jump to navigationJump to searchLine 77: | Line 77: | ||
''<span style="color:red;">No additional examples</span>'' | ''<span style="color:red;">No additional examples</span>'' | ||
+ | |||
+ | |||
Line 83: | Line 85: | ||
==Macro reference== | ==Macro reference== | ||
+ | ===InitialiseInjector=== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
Line 101: | Line 104: | ||
+ | ===TxByte=== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
Line 119: | Line 123: | ||
+ | ===RxByte=== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
Line 132: | Line 137: | ||
+ | ===GetConsoleHandle=== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
Line 145: | Line 151: | ||
+ | ===ChangeState=== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- |
Revision as of 11:50, 3 February 2023
Author | Matrix Ltd |
Version | 1.2 |
Category |
Contents
Data Transfer (API I2C) component
Comms data injector to allow a I2C bus peripheral to be attached to a comms component. The component will forward any byte transactions through to a SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly drive a physical I2C bus.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_InjectorSCADAI2C.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_InjectorSCADAI2C.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
InitialiseInjector
![]() |
InitialiseInjector |
Sets up the injector ready to receive commands or send data | |
![]() |
InjectorName |
Name of the console that will be created | |
![]() |
Return |
TxByte
![]() |
TxByte |
Puts a byte onto the comms channel. | |
![]() |
DataByte |
![]() |
Return |
RxByte
![]() |
RxByte |
Attempt to receive a byte back from the injector 0 - 255 = Valid data 256 = RX timeout no data available | |
![]() |
Return |
GetConsoleHandle
![]() |
GetConsoleHandle |
Gets the handle to the console allowing data displaying on the panel etc. | |
![]() |
Return |