Difference between revisions of "Component: EBM0016 GUI (Misc)"

From Flowcode Help
Jump to navigationJump to search
(Created page with "{| style="width:50%" |- | width="20%" style="color:gray;" | Author | Matrix |- | width="20%" style="color:gray;" | Version | 1.0 |- | width="20%" style="color:gray;" |...")
 
 
(9 intermediate revisions by the same user not shown)
Line 17: Line 17:
 
==Component Source Code==
 
==Component Source Code==
  
Please click here for the component source code: [https://www.flowcode.co.uk/wikicopy/componentsource/FC_Comp_Source_EBM0016_GUI.fcfx FC_Comp_Source_EBM0016_GUI.fcfx]
+
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_EBM0016_GUI.fcfx FC_Comp_Source_EBM0016_GUI.fcfx]
 +
 
 +
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_EBM0016_GUI.fcfx FC_Comp_Source_EBM0016_GUI.fcfx]
  
 
==Detailed description==
 
==Detailed description==
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
  
 
''No detailed description exists yet for this component''
 
''No detailed description exists yet for this component''
  
 
==Examples==
 
==Examples==
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
  
 
''<span style="color:red;">No additional examples</span>''
 
''<span style="color:red;">No additional examples</span>''
  
==Downloadable macro reference==
 
  
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
==Macro reference==
 +
 +
===GetData===
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
|-
 
|-
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetHumidity'''
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetData'''
 
|-
 
|-
| colspan="2" | Sends the given Humidity to the display, and calculates the internal values used by the simulated read macros.&nbsp;
+
| colspan="2" | Return a simulated register value for the given commands.  Recognised commands are 0xF3 (Temperature register) and 0xF5 (Humidity Register). Note that a CRC checksum is not used in simulation.&nbsp;
 
|-
 
|-
 
|-
 
|-
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT
+
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
| width="90%" | Humidity
+
| width="90%" | Command
 
|-
 
|-
| colspan="2" | Relative Humidity from 0  to 100 %&nbsp;
+
| colspan="2" | The address of the byte to return.&nbsp;
 
|-
 
|-
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
+
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
|}
 
|}
  
  
 +
===SetConsoleHandle===
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
|-
 
|-
Line 65: Line 103:
  
  
 +
===SetHumidity===
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
|-
 
|-
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetTemperature'''
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetHumidity'''
 
|-
 
|-
| colspan="2" | Sends the given temperature to the display, and calculates the internal values used by the simulated read macros.&nbsp;
+
| colspan="2" | Sends the given Humidity to the display, and calculates the internal values used by the simulated read macros.&nbsp;
 
|-
 
|-
 
|-
 
|-
 
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT
 
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT
| width="90%" | Temperature
+
| width="90%" | Humidity
 
|-
 
|-
| colspan="2" | Temperature value in Celcius,&nbsp;
+
| colspan="2" | Relative Humidity from 0  to 100 %&nbsp;
 
|-
 
|-
 
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
Line 83: Line 122:
  
  
 +
===SetTemperature===
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
 
|-
 
|-
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
 
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetData'''
+
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetTemperature'''
 
|-
 
|-
| colspan="2" | Return a simulated register value for the given commands.  Recognised commands are 0xF3 (Temperature register) and 0xF5 (Humidity Register). Note that a CRC checksum is not used in simulation.&nbsp;
+
| colspan="2" | Sends the given temperature to the display, and calculates the internal values used by the simulated read macros.&nbsp;
 
|-
 
|-
 
|-
 
|-
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE
+
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT
| width="90%" | Command
+
| width="90%" | Temperature
 
|-
 
|-
| colspan="2" | The address of the byte to return.&nbsp;
+
| colspan="2" | Temperature value in Celcius,&nbsp;
 
|-
 
|-
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT
+
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
|}
 
|}
 
 
  
  

Latest revision as of 13:09, 7 February 2023

Author Matrix
Version 1.0
Category Misc


EBM0016_GUI component

Private non-release sub-component for the EBM0016 digital Humidity/temperature sensor.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_EBM0016_GUI.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_EBM0016_GUI.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples






Macro reference

GetData

Fc9-comp-macro.png GetData
Return a simulated register value for the given commands. Recognised commands are 0xF3 (Temperature register) and 0xF5 (Humidity Register). Note that a CRC checksum is not used in simulation. 
Fc9-u8-icon.png - BYTE Command
The address of the byte to return. 
Fc9-u16-icon.png - UINT Return


SetConsoleHandle

Fc9-comp-macro.png SetConsoleHandle
Pass the parent sensor's console handle to the GUI to allow opening of the console from the 'Console' button. 
Fc9-h32-icon.png - HANDLE Handle
Handle of the console 
Fc9-void-icon.png - VOID Return


SetHumidity

Fc9-comp-macro.png SetHumidity
Sends the given Humidity to the display, and calculates the internal values used by the simulated read macros. 
Fc9-f32-icon.png - FLOAT Humidity
Relative Humidity from 0 to 100 % 
Fc9-void-icon.png - VOID Return


SetTemperature

Fc9-comp-macro.png SetTemperature
Sends the given temperature to the display, and calculates the internal values used by the simulated read macros. 
Fc9-f32-icon.png - FLOAT Temperature
Temperature value in Celcius, 
Fc9-void-icon.png - VOID Return


Property reference

Fc9-prop-icon.png Properties
Fc9-conn-icon.png Simulation
Fc9-type-10-icon.png Label
A text label to help you identify the component on the panel. 
Fc9-type-10-icon.png Sub Label
 
Fc9-type-15-icon.png Min. Temp.
Minimum termperature that can be set or displayed on the thermometer slider. 
Fc9-type-15-icon.png Max. Temp.
Maximum termperature that can be set or displayed on the thermometer slider. 
Fc9-type-21-icon.png Scale divisions
Number of numbered divisions shown on the thermometer scale. 
Fc9-type-16-icon.png I2C Data
Choose whether the I2C data is shown as decimal or hexadecimal values.