Difference between revisions of "Component: Injector (API Analog Input) (Test Injectors)"

From Flowcode Help
Jump to navigationJump to search
 
(One intermediate revision by the same user not shown)
Line 17: Line 17:
 
==Component Source Code==
 
==Component Source Code==
  
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_temp/InjectorSCADAAnalogInput.fcfx FC_Comp_Source_temp/InjectorSCADAAnalogInput.fcfx]
+
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_InjectorSCADAAnalogInput.fcfx FC_Comp_Source_InjectorSCADAAnalogInput.fcfx]
  
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_temp/InjectorSCADAAnalogInput.fcfx FC_Comp_Source_temp/InjectorSCADAAnalogInput.fcfx]
+
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_InjectorSCADAAnalogInput.fcfx FC_Comp_Source_InjectorSCADAAnalogInput.fcfx]
  
 
==Detailed description==
 
==Detailed description==
Line 77: Line 77:
  
 
''<span style="color:red;">No additional examples</span>''
 
''<span style="color:red;">No additional examples</span>''
 +
 +
 +
 +
  
  
Line 165: Line 169:
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
| width="90%" style="border-top: 2px solid #000;" | ''Return''
 
|}
 
|}
 
 
  
  

Latest revision as of 13:11, 7 February 2023

Author Matrix Ltd
Version 1.2
Category Test Injectors


Injector (API Analog Input) component

Data injector to allow a physical analog input pin to be attached to a simulated component. The component will poll for any input state changes via SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly interface with a physical I/O pin.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_InjectorSCADAAnalogInput.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_InjectorSCADAAnalogInput.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples







Macro reference

GetConsoleHandle

Fc9-comp-macro.png GetConsoleHandle
Gets the handle to the console allowing data displaying on the panel etc. 
Fc9-h32-icon.png - HANDLE Return


InitialiseInjector

Fc9-comp-macro.png InitialiseInjector
Sets up the injector ready to receive commands or send data 
Fc9-string-icon.png - STRING InjectorName
Name of the console that will be created 
Fc9-u8-icon.png - BYTE Return


RxByte

Fc9-comp-macro.png RxByte
Attempt to receive a byte back from the injector 0 - 255 = Valid data 256 = RX timeout no data available 
Fc9-u16-icon.png - UINT Return


RxByteCount

Fc9-comp-macro.png RxByteCount
Returns the number of bytes currently sat in the receive buffer. 
Fc9-u16-icon.png - UINT Return


TxByte

Fc9-comp-macro.png TxByte
Puts a byte onto the comms channel. 
Fc9-u8-icon.png - BYTE DataByte
 
Fc9-void-icon.png - VOID Return


Property reference

Fc9-prop-icon.png Properties
Fc9-type-17-icon.png API Slave
SCADA Slave component to use to pipe data to a physical SPI bus 
Fc9-type-16-icon.png Number of Pins
Specifies the number of pins the component can monitor and control. 
Fc9-type-16-icon.png Poll Rate
 
Fc9-conn-icon.png Pin 0
Fc9-type-6-icon.png Simulation ADC Pin
Pin monitored by the simulation 
Fc9-type-21-icon.png SCADA Slave ADC Pin
Pin used by the connected SCADA Slave hardware