Difference between revisions of "Component: Modbus Master (Comms: System)"
(2 intermediate revisions by the same user not shown) | |||
Line 142: | Line 142: | ||
In Flowcode each section starts from 0 so the address range is as shown. | In Flowcode each section starts from 0 so the address range is as shown. | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
Line 149: | Line 155: | ||
==Macro reference== | ==Macro reference== | ||
− | === | + | ===ChangeBaud=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ChangeBaud''' |
+ | |- | ||
+ | | colspan="2" | Changes the UART Baud rate. 1 = 1200 / 2 = 2400 / 3 = 4800 / 4 = 9600 / 5 = 19200 / 6 = 31250 7 = 38400 / 8 = 57600 / 9 = 115200 | ||
+ | |- | ||
|- | |- | ||
− | | | + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE |
+ | | width="90%" | Baud | ||
|- | |- | ||
+ | | colspan="2" | The new baud rate (0=1200, 9=115200) | ||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID |
− | | width="90%" | | + | | width="90%" style="border-top: 2px solid #000;" | ''Return'' |
+ | |} | ||
+ | |||
+ | |||
+ | ===ChangeFrameType=== | ||
+ | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
− | | | + | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] |
+ | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ChangeFrameType''' | ||
|- | |- | ||
− | | | + | | colspan="2" | Default frame type is the type set in the component properties. |
− | |||
|- | |- | ||
− | |||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE |
− | | width="90%" | | + | | width="90%" | Type |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | 0 = Modbus RTU / 1 = Modbus ASCII |
|- | |- | ||
− | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9- | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID |
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
− | === | + | ===GetResponse=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetResponse''' |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | Collects as much incoming data as possible and stored into the response buffer. The number of bytes received will be stored into location 0 of the response buffer. Return value indicates validity of incoming CRC. 0 = OK, 1 = CRC fail, 255 = No Data |
|- | |- | ||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE |
− | | width="90%" | | + | | width="90%" style="border-top: 2px solid #000;" | ''Return'' |
+ | |} | ||
+ | |||
+ | |||
+ | ===GetResponseByte=== | ||
+ | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
− | | | + | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] |
+ | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetResponseByte''' | ||
|- | |- | ||
− | | | + | | colspan="2" | Reads a byte from the last received response. The Index parametes specifies which byte to read back. |
− | |||
|- | |- | ||
− | |||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE |
− | | width="90%" | | + | | width="90%" | Index |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | 0=NumBytes, 1=SlaveAddress, 2=FunctionCode/ExceptionCode, 3=DataBytes, 4=data0, 5=data1, .. |
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 207: | Line 226: | ||
− | === | + | ===GetResponseInt=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetResponseInt''' |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | Reads a 16-bit value from the last received response. The Index parametes specifies the byte index of the value to read back. |
|- | |- | ||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE |
− | | width="90%" | | + | | width="90%" | Index |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | 4=data0, 6=data1, 8=data2, .. |
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT |
− | | width="90%" | | + | | width="90%" style="border-top: 2px solid #000;" | ''Return'' |
+ | |} | ||
+ | |||
+ | |||
+ | ===Initialise=== | ||
+ | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
− | | | + | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] |
+ | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Initialise''' | ||
|- | |- | ||
− | | | + | | colspan="2" | Starts up the UART to allow communications |
− | |||
|- | |- | ||
− | |||
|- | |- | ||
− | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9- | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID |
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
− | === | + | ===ReadAnalogInput=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadAnalogInput''' |
+ | |- | ||
+ | | colspan="2" | This command requests the analogue input register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
+ | |- | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
+ | | width="90%" | SlaveID | ||
+ | |- | ||
+ | | colspan="2" | The ID of the MODBUS slave | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
+ | | width="90%" | RegAddress | ||
+ | |- | ||
+ | | colspan="2" | Input Address: 0=10001, 1=10002, 2=10003, ... | ||
|- | |- | ||
− | | | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
+ | | width="90%" | RegCount | ||
|- | |- | ||
+ | | colspan="2" | Number of consecutive inputs to read, starting from RegAddress | ||
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 250: | Line 288: | ||
− | === | + | ===ReadCoil=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadCoil''' |
|- | |- | ||
− | | colspan="2" | This command | + | | colspan="2" | This command requests the ON/OFF status of discrete coils starting from the start CoilAddress and going through to CoilAddress plus CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. |
|- | |- | ||
|- | |- | ||
Line 273: | Line 311: | ||
|- | |- | ||
| colspan="2" | Number of consecutive coils to try and read | | colspan="2" | Number of consecutive coils to try and read | ||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 284: | Line 317: | ||
− | === | + | ===ReadDigitalInput=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadDigitalInput''' |
+ | |- | ||
+ | | colspan="2" | This command requests the ON/OFF status of discrete inputs starting from the start DataAddress and going through to DataAddress plus DataCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
+ | |- | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
+ | | width="90%" | SlaveID | ||
+ | |- | ||
+ | | colspan="2" | The ID of the MODBUS slave | ||
|- | |- | ||
− | | | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
+ | | width="90%" | DataAddress | ||
|- | |- | ||
+ | | colspan="2" | Input Address: 0=10001, 1=10002, 2=10003, ... | ||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
− | | width="90%" | | + | | width="90%" | DataCount |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | Number of consecutive inputs to read, starting from RegAddress |
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 303: | Line 346: | ||
− | === | + | ===ReadHoldingRegister=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadHoldingRegister''' |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | This command requests the analogue holding register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. |
|- | |- | ||
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
− | | width="90%" | | + | | width="90%" | SlaveID |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | The ID of the MODBUS slave |
|- | |- | ||
− | | width="10%" align="center | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
− | | width="90%" | + | | width="90%" | RegAddress |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | colspan="2" | Address: 0=40001, 1=40002, ... |
− | |||
|- | |- | ||
− | | | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
+ | | width="90%" | RegCount | ||
|- | |- | ||
+ | | colspan="2" | Number of consecutive registers to read, starting from RegAddress | ||
|- | |- | ||
− | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | |
− | |||
− | |||
− | |||
− | |||
− | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9- | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
− | === | + | ===SetCoil=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetCoil''' |
|- | |- | ||
− | | colspan="2" | This command writes the contents of | + | | colspan="2" | This command writes the contents of a discrete coil at the location CoilAddress. Returns 0 for success, 1 for CRC fail and 255 for no reply. |
|- | |- | ||
|- | |- | ||
Line 356: | Line 390: | ||
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
− | | width="90%" | | + | | width="90%" | CoilAddress |
|- | |- | ||
− | | colspan="2" | Address: 0= | + | | colspan="2" | Coil Address: 0=Coil1, 1=Coil2, 2=Coil3, ... |
|- | |- | ||
− | | width="10%" align="center" | [[File:Fc9- | + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE |
− | | width="90%" | | + | | width="90%" | CoilState |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | 0=Off, 1=On |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 375: | Line 404: | ||
− | === | + | ===SetCoils=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetCoils''' |
|- | |- | ||
− | | colspan="2" | This command | + | | colspan="2" | This command writes the contents of a series of discrete coils at the location starting at CoilAddress through to CoilAddress + CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. |
|- | |- | ||
|- | |- | ||
Line 390: | Line 419: | ||
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
− | | width="90%" | | + | | width="90%" | CoilAddress |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | Coil Address: 0=Coil1, 1=Coil2, 2=Coil3, ... |
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
− | | width="90%" | | + | | width="90%" | CoilCount |
+ | |- | ||
+ | | colspan="2" | Number of consecutive coils to try and read | ||
+ | |- | ||
+ | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE | ||
+ | | width="90%" | CoilData | ||
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | An array of bytes each containing 8 1-bit coil values |
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | ||
Line 433: | Line 467: | ||
− | === | + | ===SetHoldingRegisters=== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
|- | |- | ||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | ||
− | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | ''' | + | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetHoldingRegisters''' |
|- | |- | ||
− | + | | colspan="2" | This command writes the contents of several holding registers starting at the location RegAddress through to location RegAddress + RegCount . Returns 0 for success, 1 for CRC fail and 255 for no reply. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | colspan="2" | This command | ||
|- | |- | ||
|- | |- | ||
Line 467: | Line 482: | ||
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
− | | width="90%" | | + | | width="90%" | RegAddress |
|- | |- | ||
− | | colspan="2" | | + | | colspan="2" | Address: 0=40001, 1=40002, ... |
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT | ||
− | | width="90%" | | + | | width="90%" | RegCount |
|- | |- | ||
− | | colspan="2" | Number of consecutive | + | | colspan="2" | Number of consecutive registers to write, starting from RegAddress |
|- | |- | ||
− | | width="10%" align="center | + | | width="10%" align="center" | [[File:Fc9-u16-icon.png]] - UINT |
− | | width="90%" | + | | width="90%" | RegValue |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | colspan="2" | Array of values to send to the registers |
− | |||
|- | |- | ||
− | + | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | |
− | |||
− | |||
− | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9- | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
− | |||
− | |||
Latest revision as of 13:12, 7 February 2023
Author | Matrix Ltd. |
Version | 2.1 |
Category | Comms: System |
Contents
Modbus Master component
Modbus component for talking to Modbus compatible hardware via RS232 or RS485.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_Modbus.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_Modbus.fcfx
Detailed description
No detailed description exists yet for this component
Examples
CT-2EA Modbus Electronic kWh Meter
Example to talk to a CT-2EA Modbus Electronic kWh Meter
Setup to communicate via Embedded UART1 or Simulated COM3
Console data generated by the working example running in the simulation and communicating via the COM port.
Master and Slave example using vNet
Example of communicating using Modbus Master and Slave using two instances of Flowcode and the vNet injector component.
Addressing
In Modbus the addressing protocol looks like this.
Data Type | Common name | Starting address | Ending Address | Flowcode Start Address | Flowcode End Address |
Modbus Coils | Bits, binary values, flags | 00001 | 10000 | 0 | 9999 |
Digital Inputs | Binary inputs | 10001 | 30000 | 0 | 19999 |
Analog Inputs | Binary inputs | 30001 | 40000 | 0 | 9999 |
Modbus Registers | Analog values, variables | 40001 | 60000 | 0 | 19999 |
In Flowcode each section starts from 0 so the address range is as shown.
Macro reference
ChangeBaud
ChangeFrameType
![]() |
ChangeFrameType |
Default frame type is the type set in the component properties. | |
![]() |
Type |
0 = Modbus RTU / 1 = Modbus ASCII | |
![]() |
Return |
GetResponse
GetResponseByte
GetResponseInt
![]() |
GetResponseInt |
Reads a 16-bit value from the last received response. The Index parametes specifies the byte index of the value to read back. | |
![]() |
Index |
4=data0, 6=data1, 8=data2, .. | |
![]() |
Return |
Initialise
![]() |
Initialise |
Starts up the UART to allow communications | |
![]() |
Return |
ReadAnalogInput
ReadCoil
ReadDigitalInput
ReadHoldingRegister
SetCoil
SetCoils
SetHoldingRegister
SetHoldingRegisters