Component: Indicator Gauge (Indicators): Difference between revisions
Appearance
XML import |
m Text replacement - "style="background-color:#EAE1EA;"" to "class="mtx-class-propfolder"" |
||
| (17 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
{| style="width:50%" | |||
{| | |||
|- | |- | ||
| width="20%" style="color: gray;" | Author | | width="20%" style="color:gray;" | Author | ||
| Matrix Ltd | | Matrix Ltd | ||
|- | |- | ||
| width="20%" style="color: gray;" | Version | | width="20%" style="color:gray;" | Version | ||
| 1.3 | | 1.3 | ||
|- | |- | ||
| width="20%" style="color: gray;" | Category | | width="20%" style="color:gray;" | Category | ||
| Indicators | | Indicators | ||
|} | |} | ||
==Indicator Gauge component== | |||
Simulation only round gauge/dial for SCADA applications. The range of values displayed is easily adjusted. | |||
== | ==Component Source Code== | ||
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_IndicatorGauge.fcfx FC_Comp_Source_IndicatorGauge.fcfx] | |||
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_IndicatorGauge.fcfx FC_Comp_Source_IndicatorGauge.fcfx] | |||
== | ==Detailed description== | ||
'' | ''No detailed description exists yet for this component'' | ||
==Examples== | |||
''<span style="color:red;">No additional examples</span>'' | |||
==Macro reference== | |||
===GetValue=== | |||
{| class="mtx-class-macrotable wikitable" | |||
|- | |||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" class="mtx-class-macrohead" | '''GetValue''' | |||
|- | |||
| colspan="2" | Get the current scale value - this will be the most recent value set using "SetValue", or from the most recent mouse click if the component is in "Control" mode. | |||
|- | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-f32-icon.png]] - FLOAT | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
===SetRange=== | |||
{| class="mtx-class-macrotable wikitable" | |||
|- | |||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" class="mtx-class-macrohead" | '''SetRange''' | |||
|- | |||
| colspan="2" | Set the minimum and maximum values of the scale | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT | |||
| width="90%" | Minimum | |||
|- | |||
| colspan="2" | Minimum value for the scale | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT | |||
| width="90%" | Maximum | |||
|- | |||
| colspan="2" | Maximum value for the scale | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
===SetValue=== | |||
{| class="mtx-class-macrotable wikitable" | |||
|- | |||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" class="mtx-class-macrohead" | '''SetValue''' | |||
|- | |||
| colspan="2" | Set the pointer to the given value on the scale. Returns the angle required to point at the given value. | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-f32-icon.png]] - FLOAT | |||
| width="90%" | Value | |||
|- | |||
| colspan="2" | The value on the scale to move the pointer to. | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-f32-icon.png]] - FLOAT | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
==Property reference== | |||
{| class="mtx-class-macrotable wikitable" | |||
|- | |||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | |||
| width="90%" class="mtx-class-macrohead" | '''Properties''' | |||
Decides if a label is shown detailing current setting of the control knob. | |- | ||
|- | |||
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | |||
| width="90%" class="mtx-class-propfolder" | Range | |||
|- | |||
|- | |||
Sets the label colour | | width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | ||
| width="90%" | Minimum | |||
|- | |||
| colspan="2" | Minimum value that the meter will show (fully counter-clockwise) | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
Adds a unit to the end of the label | | width="90%" | Maximum | ||
|- | |||
| colspan="2" | Maximum value that the meter will show (fully clockwsie) | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-16-icon.png]] | |||
| width="90%" | Startup State | |||
Number of decinal points to draw on the label | |- | ||
| colspan="2" | Sets the initial value when loading the project or when the runtime starts. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
| width="90%" | Default Value | |||
|- | |||
Sets the size of the label on the panel, default 1.0 | | colspan="2" | The default value used on initialise or runtime start. | ||
|- | |||
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | |||
| width="90%" class="mtx-class-propfolder" | Title | |||
|- | |||
|- | |||
Number of decimal places to show on the number labels. | | width="10%" align="center" | [[File:Fc9-type-7-icon.png]] | ||
| width="90%" | Show Title | |||
|- | |||
| colspan="2" | Decides if the component title is shown | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-1-icon.png]] | |||
Height of the number label text. | | width="90%" | Title Colour | ||
|- | |||
| colspan="2" | Title Label Color | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-10-icon.png]] | |||
| width="90%" | Title Text | |||
Font for the number labels. | |- | ||
| colspan="2" | Title Label Text | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
| width="90%" | Title Scale | |||
|- | |||
Set the number of major scale divisions - these will be given number value labels. | | colspan="2" | Controls the size of the title text on the panel, default 1.2 | ||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
| width="90%" | Title Offset | |||
|- | |||
| colspan="2" | Distance above component center to draw the title | |||
Number of smaller scale divisions in between the numbered ones. | |- | ||
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | |||
| width="90%" class="mtx-class-propfolder" | Label | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-7-icon.png]] | |||
Colour for the meter background. | | width="90%" | Show Label | ||
|- | |||
| colspan="2" | Decides if a label is shown detailing current setting of the control knob. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-1-icon.png]] | |||
| width="90%" | Label Colour | |||
Colour for the number labels for greater than zero. | |- | ||
| colspan="2" | Sets the label colour | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-10-icon.png]] | |||
| width="90%" | Label Units | |||
|- | |||
Colour for the number labels for value greater than zero. | | colspan="2" | Adds a unit to the end of the label | ||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-21-icon.png]] | |||
| width="90%" | Label Decimal Points | |||
|- | |||
| colspan="2" | Number of decinal points to draw on the label | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
| width="90%" | Label Scale | |||
|- | |||
| colspan="2" | Sets the size of the label on the panel, default 1.0 | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-15-icon.png]] | |||
| width="90%" | Label Offset | |||
|- | |||
| colspan="2" | Distance above component center to draw the label | |||
|- | |||
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | |||
| width="90%" class="mtx-class-propfolder" | Numeric Labels | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |||
| width="90%" | Decimals | |||
|- | |||
| colspan="2" | Number of decimal places to show on the number labels. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |||
| width="90%" | Text Size % | |||
|- | |||
| colspan="2" | Height of the number label text. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-3-icon.png]] | |||
| width="90%" | Font | |||
|- | |||
| colspan="2" | Font for the number labels. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |||
| width="90%" | Divisions | |||
|- | |||
| colspan="2" | Set the number of major scale divisions - these will be given number value labels. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-14-icon.png]] | |||
| width="90%" | Subdivisions | |||
|- | |||
| colspan="2" | Number of smaller scale divisions in between the numbered ones. | |||
|- | |||
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | |||
| width="90%" class="mtx-class-propfolder" | Scheme | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-2-icon.png]] | |||
| width="90%" | BG Color | |||
|- | |||
| colspan="2" | Colour for the meter background. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-1-icon.png]] | |||
| width="90%" | Positive Color | |||
|- | |||
| colspan="2" | Colour for the number labels for greater than zero. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-1-icon.png]] | |||
| width="90%" | Negative Color | |||
|- | |||
| colspan="2" | Colour for the number labels for value greater than zero. | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-type-1-icon.png]] | |||
| width="90%" | Needle Color | |||
|- | |||
| colspan="2" | | |||
|} | |||
Latest revision as of 14:37, 13 July 2026
| Author | Matrix Ltd |
| Version | 1.3 |
| Category | Indicators |
Indicator Gauge component
Simulation only round gauge/dial for SCADA applications. The range of values displayed is easily adjusted.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_IndicatorGauge.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_IndicatorGauge.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
GetValue
| GetValue | |
| Get the current scale value - this will be the most recent value set using "SetValue", or from the most recent mouse click if the component is in "Control" mode. | |
| Return | |
SetRange
| SetRange | |
| Set the minimum and maximum values of the scale | |
| Minimum | |
| Minimum value for the scale | |
| Maximum | |
| Maximum value for the scale | |
| Return | |
SetValue
| SetValue | |
| Set the pointer to the given value on the scale. Returns the angle required to point at the given value. | |
| Value | |
| The value on the scale to move the pointer to. | |
| Return | |