Jump to content

Component: EBM004 GUI (Misc): Difference between revisions

From Flowcode Help
m Text replacement - "width="10%" align="center" style="background-color:#D8C9D8;" align="center"" to "width="10%" align="center" class="mtx-class-macrohead""
m Text replacement - "style="background-color:#EAE1EA;"" to "class="mtx-class-propfolder""
 
(3 intermediate revisions by the same user not shown)
Line 95: Line 95:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadByte'''
| width="90%" class="mtx-class-macrohead" | '''ReadByte'''
|-
|-
| colspan="2" | Get the data from the MSB of a sensor register. 
| colspan="2" | Get the data from the MSB of a sensor register. 
Line 114: Line 114:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadFloat'''
| width="90%" class="mtx-class-macrohead" | '''ReadFloat'''
|-
|-
| colspan="2" | Get the temperature register value converted into an actual floating point temperature readng in Celcius. 
| colspan="2" | Get the temperature register value converted into an actual floating point temperature readng in Celcius. 
Line 128: Line 128:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadInt'''
| width="90%" class="mtx-class-macrohead" | '''ReadInt'''
|-
|-
| colspan="2" | Get the complete 16bit integer value of the sensor's temperature register. 
| colspan="2" | Get the complete 16bit integer value of the sensor's temperature register. 
Line 147: Line 147:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetConsoleHandle'''
| width="90%" class="mtx-class-macrohead" | '''SetConsoleHandle'''
|-
|-
| colspan="2" | Pass the parent sensor's console handle to the GUI to allow opening of the console from the 'Console' button. 
| colspan="2" | Pass the parent sensor's console handle to the GUI to allow opening of the console from the 'Console' button. 
Line 166: Line 166:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetMinMax'''
| width="90%" class="mtx-class-macrohead" | '''SetMinMax'''
|-
|-
| colspan="2" | Set the minimum and maximum temperature values that can be shown and set on the thermometer readout. 
| colspan="2" | Set the minimum and maximum temperature values that can be shown and set on the thermometer readout. 
Line 190: Line 190:
|-
|-
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetTemperature'''
| width="90%" class="mtx-class-macrohead" | '''SetTemperature'''
|-
|-
| colspan="2" | Sends the given temperature to the display, and calculates the internal values used by the simulated read macros. 
| colspan="2" | Sends the given temperature to the display, and calculates the internal values used by the simulated read macros. 
Line 209: Line 209:
{| class="mtx-class-macrotable wikitable"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-prop-icon.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Properties'''  
| width="90%" class="mtx-class-macrohead" | '''Properties'''  
|-
|-
|-
|-
| width="10%" align="center" style="background-color:#EAE1EA;" | [[File:Fc9-conn-icon.png]]
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]]
| width="90%" style="background-color:#EAE1EA; color:#4B008D;" | Simulation
| width="90%" class="mtx-class-propfolder" | Simulation
|-
|-
|-
|-

Latest revision as of 14:36, 13 July 2026

Author Matrix
Version 1.0
Category Misc


EBM004_GUI component

Private non-release sub-component for the EBM004 digital temperature sensor.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_EBM004_GUI.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_EBM004_GUI.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples







Macro reference

ReadByte

ReadByte
Get the data from the MSB of a sensor register. 
- BYTE Address
The address of the byte to return. 
- BYTE Return


ReadFloat

ReadFloat
Get the temperature register value converted into an actual floating point temperature readng in Celcius. 
- FLOAT Return


ReadInt

ReadInt
Get the complete 16bit integer value of the sensor's temperature register. 
- BYTE Address
The address of the byte to return. 
- INT Return


SetConsoleHandle

SetConsoleHandle
Pass the parent sensor's console handle to the GUI to allow opening of the console from the 'Console' button. 
- HANDLE Handle
Handle of the console 
- VOID Return


SetMinMax

SetMinMax
Set the minimum and maximum temperature values that can be shown and set on the thermometer readout. 
- FLOAT Min
Minimum Value 
- FLOAT Max
Maximum Value 
- VOID Return


SetTemperature

SetTemperature
Sends the given temperature to the display, and calculates the internal values used by the simulated read macros. 
- FLOAT Temperature
Zero to one value - representing min-max of the sensor. 
- VOID Return


Property reference

Properties
Simulation
Label
A text label to help you identify the component on the panel. 
Min. Temp.
Minimum termperature that can be set or displayed on the thermometer slider. 
Max. Temp.
Maximum termperature that can be set or displayed on the thermometer slider. 
Scale divisions
Number of numbered divisions shown on the thermometer scale. 
I2C Data