| ==Macro reference== | ==Macro reference== | ||
| + | ===IncrementWiper=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
| Line 101: | Line 104: | ||
| + | ===DecrementWiper=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
| Line 119: | Line 123: | ||
| + | ===SetWiper=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
| Line 147: | Line 152: | ||
| + | ===ReadAddress=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
| Line 165: | Line 171: | ||
| + | ===WriteAddress=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
| Line 188: | Line 195: | ||
| + | ===Initialise=== | ||
| {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| |- | |- | ||
Revision as of 11:51, 3 February 2023
| Author | Matrix TSL | 
| Version | 1.0 | 
| Category | Analog Output | 
Contents
Digital Potentiometer (MCP44XX) component
The MCP44XX device range supports 4 digital potentiometers or rheostat outputs. 129 or 257 possible output resistance values for each channel.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_MCP44xx_Digital_Pot.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_MCP44xx_Digital_Pot.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
IncrementWiper
|   | IncrementWiper | 
| Increments a single volatile wiper value | |
|  - BYTE | Index | 
| Range: 0-3 | |
|  - VOID | Return | 
DecrementWiper
|   | DecrementWiper | 
| Decrements a single volatile wiper value | |
|  - BYTE | Index | 
| Range: 0-3 | |
|  - VOID | Return | 
SetWiper
|   | SetWiper | 
| Sets the value of a single wiper | |
|  - BYTE | Index | 
| Range: 0-3 | |
|  - UINT | Value | 
| 129 Taps Range: 0-128 / 257 Taps Range: 0-256 | |
|  - BOOL | MemoryType | 
| 0=Volatile, 1=Nonvolatile | |
|  - VOID | Return | 
ReadAddress
|   | ReadAddress | 
| Reads a value from one of the registers on the device | |
|  - BYTE | Address | 
| Range: 0-15 | |
|  - UINT | Return | 
WriteAddress
|   | WriteAddress | 
| Writes a value to one of the registers on the device | |
|  - BYTE | Address | 
| Range: 0-15 | |
|  - UINT | Value | 
| Range: 0-256 | |
|  - VOID | Return | 
Initialise
|   | Initialise | 
| Startup the I2C peripheral ready for communications. | |
|  - VOID | Return | 