Jump to content

Component: Beam Breaker (Light): Difference between revisions

From Flowcode Help
No edit summary
No edit summary
Line 17: Line 17:
==Component Source Code==
==Component Source Code==


Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_Beam_breaker.fcfx FC_Comp_Source_Beam_breaker.fcfx]
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_temp/Beam_breaker.fcfx FC_Comp_Source_temp/Beam_breaker.fcfx]


Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_Beam_breaker.fcfx FC_Comp_Source_Beam_breaker.fcfx]
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_temp/Beam_breaker.fcfx FC_Comp_Source_temp/Beam_breaker.fcfx]


==Detailed description==
==Detailed description==
Line 52: Line 52:


''<span style="color:red;">No additional examples</span>''
''<span style="color:red;">No additional examples</span>''





Revision as of 11:59, 3 February 2023

Author Matrix Ltd
Version 1.1
Category Light


Beam Breaker component

Automatically sets and resets a pin depending on whether a panel object breaks the 'light beam'. Can also send simulation notification events.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_temp/Beam_breaker.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_temp/Beam_breaker.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples




Macro reference

ReadState

ReadState
Get the current collision state. The 'Polarity' property will affect whether a collision is represented by a high or low state. 
- BYTE Return


SetTarget

SetTarget
Set the object that you want to test for collision with. If this is not called, or is called with handle = 0, collisions will be tested against every panel object that has 'Solid' status. NB) Specifying an object will save CPU power!! 
- HANDLE Target
The object to test for collision with. 
- VOID Return


WaitUntilHigh

WaitUntilHigh
Pause the program until the detector goes high. 'Polarity' will affect whether high value represents a collision or separation. NB) In simulation, only use this macro if testing for collision with animated or timer driven objects!! 
- VOID Return


WaitUntilLow

WaitUntilLow
Pause the program until the detector goes low. 'Polarity' will affect whether low value represents a collision or separation. NB) In simulation, only use this macro if testing for collision with animated or timer driven objects!! 
- VOID Return



Property reference

Properties
Connections
Pin
Chip pin that the beam breaker is connected to,. 
Polarity
Active High = Pin is on when beam is broken, off when beam is intact. Active Low = Pin is off when beam is broken, on when beam is intact. 
Simulation
Target
Choose a specific object to test for breaking the beam. If none is chosen, will check against any other object with 'Solid' status - note, checking all objects increases the CPU load!! 
Range
Set the distance between the transmitter and receiver 
Show Beam
Shows the 'light beam' on screen - arrow points from transmitter to receiver. 
Timer Interval (ms)
Time in milliseconds between collision scans. Small time = Greater CPU load Large time = More like to miss brief collisions. 
Notification
Notify
Whether or not to notify the component parent of any changes. Data will be zero or one (the current pin value).