Difference between revisions of "Component: Digital Potentiometer (MCP44XX) (Analog Output)"
From Flowcode Help
Jump to navigationJump to search| Line 77: | Line 77: | ||
''<span style="color:red;">No additional examples</span>'' | ''<span style="color:red;">No additional examples</span>'' | ||
| + | |||
| + | |||
| Line 209: | Line 211: | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
| − | |||
| − | |||
Revision as of 12:21, 3 February 2023
| Author | Matrix TSL |
| Version | 1.0 |
| Category | Analog Output |
Contents
Digital Potentiometer (MCP44XX) component
The MCP44XX device range supports 4 digital potentiometers or rheostat outputs. 129 or 257 possible output resistance values for each channel.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_temp/MCP44xx_Digital_Pot.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_temp/MCP44xx_Digital_Pot.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
DecrementWiper
| DecrementWiper | |
| Decrements a single volatile wiper value | |
| Index | |
| Range: 0-3 | |
| Return | |
IncrementWiper
| IncrementWiper | |
| Increments a single volatile wiper value | |
| Index | |
| Range: 0-3 | |
| Return | |
Initialise
| Initialise | |
| Startup the I2C peripheral ready for communications. | |
| Return | |
ReadAddress
| ReadAddress | |
| Reads a value from one of the registers on the device | |
| Address | |
| Range: 0-15 | |
| Return | |
SetWiper
| SetWiper | |
| Sets the value of a single wiper | |
| Index | |
| Range: 0-3 | |
| Value | |
| 129 Taps Range: 0-128 / 257 Taps Range: 0-256 | |
| MemoryType | |
| 0=Volatile, 1=Nonvolatile | |
| Return | |
WriteAddress
| WriteAddress | |
| Writes a value to one of the registers on the device | |
| Address | |
| Range: 0-15 | |
| Value | |
| Range: 0-256 | |
| Return | |