Data injector to allow a physical digital input pin to be attached to a simulated component. The component will poll for any input state changes via SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly interface with a physical I/O pin. | Data injector to allow a physical digital input pin to be attached to a simulated component. The component will poll for any input state changes via SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly interface with a physical I/O pin. | ||
==Component | ==Component Source Code== | ||
Please click here for the component source code: [https://www.flowcode.co.uk/wikicopy/componentsource/FC_Comp_Source_InjectorSCADADigitalInput.fcfx FC_Comp_Source_InjectorSCADADigitalInput.fcfx] | |||
==Detailed description== | ==Detailed description== | ||
| Line 34: | Line 36: | ||
==Examples== | ==Examples== | ||
| Line 50: | Line 54: | ||
==Downloadable macro reference== | ==Downloadable macro reference== | ||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |||
|- | |||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''InitialiseInjector''' | |||
|- | |||
| colspan="2" | Sets up the injector ready to receive commands or send data | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-string-icon.png]] - STRING | |||
| width="90%" | InjectorName | |||
|- | |||
| colspan="2" | Name of the console that will be created | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u8-icon.png]] - BYTE | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |||
|- | |||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''RxByteCount''' | |||
|- | |||
| colspan="2" | Returns the number of bytes currently sat in the receive buffer. | |||
|- | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |||
|- | |||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''TxByte''' | |||
|- | |||
| colspan="2" | Puts a byte onto the comms channel. | |||
|- | |||
|- | |||
| width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE | |||
| width="90%" | DataByte | |||
|- | |||
| colspan="2" | | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-void-icon.png]] - VOID | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | |||
|- | |||
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]] | |||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''RxByte''' | |||
|- | |||
| colspan="2" | Attempt to receive a byte back from the injector 0 - 255 = Valid data 256 = RX timeout no data available | |||
|- | |||
|- | |||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT | |||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | |||
|} | |||
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
| Line 89: | Line 155: | ||
| colspan="2" | | | colspan="2" | | ||
|- | |- | ||
| width="10%" align="center" | [[File:Fc9- | | width="10%" align="center" style="background-color:#EAE1EA;" | [[File:Fc9-conn-icon.png]] | ||
| width="90%" | | | width="90%" style="background-color:#EAE1EA; color:#4B008D;" | Pin 0 | ||
|- | |- | ||
|- | |- | ||
| width="10%" align="center" | [[File:Fc9-type-5-icon.png]] | | width="10%" align="center" | [[File:Fc9-type-5-icon.png]] | ||
| Line 108: | Line 168: | ||
|- | |- | ||
| colspan="2" | Pin used by the connected SCADA Slave hardware | | colspan="2" | Pin used by the connected SCADA Slave hardware | ||
|} | |} | ||
Revision as of 17:47, 9 November 2022
| Author | Matrix Ltd |
| Version | 1.2 |
| Category | Test Injectors |
Injector (API Digital Input) component
Data injector to allow a physical digital input pin to be attached to a simulated component. The component will poll for any input state changes via SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly interface with a physical I/O pin.
Component Source Code
Please click here for the component source code: FC_Comp_Source_InjectorSCADADigitalInput.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Downloadable macro reference
| InitialiseInjector | |
| Sets up the injector ready to receive commands or send data | |
| InjectorName | |
| Name of the console that will be created | |
| Return | |
| RxByteCount | |
| Returns the number of bytes currently sat in the receive buffer. | |
| Return | |
| TxByte | |
| Puts a byte onto the comms channel. | |
| DataByte | |
| Return | |
| RxByte | |
| Attempt to receive a byte back from the injector 0 - 255 = Valid data 256 = RX timeout no data available | |
| Return | |
| GetConsoleHandle | |
| Gets the handle to the console allowing data displaying on the panel etc. | |
| Return | |