Jump to content

Component: K8055D (Third Party): Difference between revisions

From Flowcode Help
Created page with "{| style="width:50%" |- | width="20%" style="color:gray;" | Author | Matrix Ltd |- | width="20%" style="color:gray;" | Version | 2.3 |- | width="20%" style="color:gray..."
 
No edit summary
Line 20: Line 20:


==Detailed description==
==Detailed description==


''No detailed description exists yet for this component''
''No detailed description exists yet for this component''


==Examples==
==Examples==


''<span style="color:red;">No additional examples</span>''
''<span style="color:red;">No additional examples</span>''


==Downloadable macro reference==
==Macro reference==


{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"

Revision as of 14:11, 20 January 2023

Author Matrix Ltd
Version 2.3
Category Third Party


K8055D component

Support for the Velleman K8055 USB input/output board. Allows Flowcode to communicate with up to four K8055 boards, or to simulate them with interactive on-screen controls. All digital and analog I/O functions are supported.

Component Source Code

Please click here for the component source code: FC_Comp_Source_K8055D.fcsx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples

Macro reference

GetCount
Read the value of the chosen counter for the currently selected board. 
- INT Counter
The counter to read (1 or 2) 
- UINT Return


GetAnalogIn
Read analog input 1 or 2 
- INT Input
Which input to read (1 ro 2) 
- INT Return


SetAnalogOut
Sets the chosen analog output to the given value (0-255) 
- BYTE Output
Which output to set the value for (1 ro 2) 
- BYTE Value
Value to set (0-255) 
- VOID Return


SetDigitalOut
Sets the state of the output given by the output index (1 to 8) 
- BYTE Out
Number of the output to set the value for 
- BOOL Value
 
- VOID Return


GetDigitalByte
Read all five inputs at once, returning them as a bit pattern in a byte. The upper three bits will always be zero. 
- INT Return


ResetCount
Resets the chosen counter of the currently selected board. 
- INT Counter
Which counter to reset (1 or 2) 
- VOID Return


GetDevices
Returns a value representing the available devices. Device is a binary value where bit(N) set = device at address (N) is connected. 
- INT Return


Select
Selects the board address to send to and receive data from. Echos the address if the selection is valid. Returns -1 if there is no device available at that address. 
- INT Address
The address off the board to be selected (0...3). 
- INT Return


SetDigitalByte
Sets all eight digital outputs according to the individual bits of the Value parameter. 
- BYTE Value
Value to send to the selected board. 
- VOID Return


GetDigitalIn
Read the individual input at the given index (1..5) 
- INT Input
Which input to read (1 to 5) 
- INT Return


SetCountDebounce
Set the amount of time allowed for switches to settle before being counted as a new event to count. 
- INT Counter
Which counter to make a setting for (1 or 2) 
- INT DebounceTime
Settling time for switch debouncing in milliseconds 
- VOID Return



Property reference

Properties
Simulation
Addr 0
Use software simulation to emulate a board connected at address 0. 
Addr 1
Use software simulation to emulate a board connected at address 1. 
Addr 2
Use software simulation to emulate a board connected at address 2. 
Addr 3
Use software simulation to emulate a board connected at address 3. 
Hardware
Scan
Request a scan of the currently connected hardware to detect what Velleman boards are connected and at what addresses. Where hardware is not detected at an addess, a System Panel simulation will be used instead where one has been requested in the properties.