Difference between revisions of "Component: Modbus Slave (SCADA) (Comms: System)"
From Flowcode Help
Jump to navigationJump to search| Line 20: | Line 20: | ||
==Detailed description== | ==Detailed description== | ||
| + | |||
| + | |||
| Line 36: | Line 38: | ||
==Examples== | ==Examples== | ||
| + | |||
| + | |||
| Line 53: | Line 57: | ||
| − | == | + | ==Macro reference== |
{| class="wikitable" style="width:60%; background-color:#FFFFFF;" | {| class="wikitable" style="width:60%; background-color:#FFFFFF;" | ||
Revision as of 14:12, 20 January 2023
| Author | Matrix TSL |
| Version | 1.0 |
| Category | Comms: System |
Contents
Modbus Slave (SCADA) component
Modbus component for creating Modbus compatible slave hardware via RS232 or RS485.
Component Source Code
Please click here for the component source code: FC_Comp_Source_Modbus_Slave_SCADA.fcsx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
| ReadHoldingRegister | |
| Reads the value of a single holding register. | |
| Address | |
| Coil Address | |
| Return | |
| SetCoil | |
| Sets the state of a single digital coil. | |
| Address | |
| Coil Address | |
| State | |
| 0=off, 1=on | |
| Return | |
| SetDigitalInput | |
| Sets the state of a single digital input. | |
| Address | |
| Coil Address | |
| State | |
| 0=off, 1=on | |
| Return | |
| ChangeFrameType | |
| Default frame type is the type set in the component properties. | |
| Type | |
| 0 = Modbus RTU / 1 = Modbus ASCII | |
| Return | |
| SetHoldingRegister | |
| Sets the state of a single holding register. | |
| Address | |
| Coil Address | |
| Value | |
| Analogue Value range 0 - 65535 | |
| Return | |
| ReadAnalogInput | |
| Reads the value of a single analogue input. | |
| Address | |
| Coil Address | |
| Return | |
| GetLastIncoming | |
| Gets a value from the last incoming command. Index 0 = 0 Read / 1 Write Index 1 = 0 Coils / 1 DigInput / 2 AnInput / 3 Register Index 2 = Address Index 3 = Number | |
| Return | |
| SetAnalogInput | |
| Sets the state of a single analogue input. | |
| Address | |
| Coil Address | |
| Value | |
| Analogue Value range 0 - 65535 | |
| Return | |
| Initialise | |
| Starts up the UART to allow communications and initialises the states of the various Modbus Coils, Inputs and Registers to 0. | |
| Return | |