Jump to content

Component: Data Transfer (API I2C) (): Difference between revisions

From Flowcode Help
No edit summary
No edit summary
Line 77: Line 77:


''<span style="color:red;">No additional examples</span>''
''<span style="color:red;">No additional examples</span>''




Line 83: Line 85:
==Macro reference==
==Macro reference==


===InitialiseInjector===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
|-
|-
Line 101: Line 104:




===TxByte===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
|-
|-
Line 119: Line 123:




===RxByte===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
|-
|-
Line 132: Line 137:




===GetConsoleHandle===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
|-
|-
Line 145: Line 151:




===ChangeState===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
|-
|-

Revision as of 11:50, 3 February 2023

Author Matrix Ltd
Version 1.2
Category


Data Transfer (API I2C) component

Comms data injector to allow a I2C bus peripheral to be attached to a comms component. The component will forward any byte transactions through to a SCADA Slave enabled hardware. Enabling the Flowcode simulation runtime to directly drive a physical I2C bus.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_InjectorSCADAI2C.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_InjectorSCADAI2C.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples




Macro reference

InitialiseInjector

InitialiseInjector
Sets up the injector ready to receive commands or send data 
- STRING InjectorName
Name of the console that will be created 
- BYTE Return


TxByte

TxByte
Puts a byte onto the comms channel. 
- BYTE DataByte
 
- VOID Return


RxByte

RxByte
Attempt to receive a byte back from the injector 0 - 255 = Valid data 256 = RX timeout no data available 
- UINT Return


GetConsoleHandle

GetConsoleHandle
Gets the handle to the console allowing data displaying on the panel etc. 
- HANDLE Return


ChangeState

ChangeState
Sets the state of the bus. SPI - Controls the chip select pin I2C - Controls the start/restart/stop status 
- BYTE State
SPI: 0=CSLow, 1=CSHigh I2C: 0=Stop, 1=Start, 2=Restart, 3=LastRx 
- VOID Return



Property reference

Properties
SCADA Slave
SCADA Slave component to use to pipe data to a physical SPI bus