Component: ADC Template 2D (Analog Input): Difference between revisions
Appearance
m Text replacement - "width="10%" align="center" style="background-color:#D8C9D8;"" to "width="10%" align="center" class="mtx-class-macrohead"" |
m Text replacement - "width="90%" style="background-color:#D8C9D8; color:#4B008D;"" to "width="90%" class="mtx-class-macrohead"" |
||
| Line 71: | Line 71: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetAverageByte''' | ||
|- | |- | ||
| colspan="2" | Function call to read the ADC as a byte average sample over time | | colspan="2" | Function call to read the ADC as a byte average sample over time | ||
| Line 95: | Line 95: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetAverageInt''' | ||
|- | |- | ||
| colspan="2" | Function call to read the ADC as a full width average sample over time | | colspan="2" | Function call to read the ADC as a full width average sample over time | ||
| Line 119: | Line 119: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetByte''' | ||
|- | |- | ||
| colspan="2" | Blocking call to read the ADC as a byte | | colspan="2" | Blocking call to read the ADC as a byte | ||
| Line 133: | Line 133: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetInt''' | ||
|- | |- | ||
| colspan="2" | Blocking call to read the ADC at full bit depth | | colspan="2" | Blocking call to read the ADC at full bit depth | ||
| Line 147: | Line 147: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetSampleBits''' | ||
|- | |- | ||
| colspan="2" | Gets the number of bits per sample | | colspan="2" | Gets the number of bits per sample | ||
| Line 161: | Line 161: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetSpeedFilter''' | ||
|- | |- | ||
| colspan="2" | Gets the Conversion speed filter string Use in Component.Property.SetFilter() | | colspan="2" | Gets the Conversion speed filter string Use in Component.Property.SetFilter() | ||
| Line 175: | Line 175: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetString''' | ||
|- | |- | ||
| colspan="2" | Reads the ADC as a direct voltage and returns as a string | | colspan="2" | Reads the ADC as a direct voltage and returns as a string | ||
| Line 189: | Line 189: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetVoltage''' | ||
|- | |- | ||
| colspan="2" | Reads the ADC as a direct voltage | | colspan="2" | Reads the ADC as a direct voltage | ||
| Line 203: | Line 203: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawAverageByte''' | ||
|- | |- | ||
| colspan="2" | Background call to read the ADC as a byte average sample over time Call Enable() before this | | colspan="2" | Background call to read the ADC as a byte average sample over time Call Enable() before this | ||
| Line 227: | Line 227: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawAverageInt''' | ||
|- | |- | ||
| colspan="2" | Background call to read the ADC as a full width average sample over time Call Enable() before this | | colspan="2" | Background call to read the ADC as a full width average sample over time Call Enable() before this | ||
| Line 251: | Line 251: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawDisable''' | ||
|- | |- | ||
| colspan="2" | Disables the previously enabled ADC channel and converts back to digital mode. | | colspan="2" | Disables the previously enabled ADC channel and converts back to digital mode. | ||
| Line 265: | Line 265: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawEnable''' | ||
|- | |- | ||
| colspan="2" | Enables and configures the ADC channel to be an analogue input. Only one ADC channel can be enabled at a time. Any RAW functions will reference the last enabled channel only. | | colspan="2" | Enables and configures the ADC channel to be an analogue input. Only one ADC channel can be enabled at a time. Any RAW functions will reference the last enabled channel only. | ||
| Line 279: | Line 279: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawSampleByte''' | ||
|- | |- | ||
| colspan="2" | Background call to read the ADC as a byte Call Enable() before this | | colspan="2" | Background call to read the ADC as a byte Call Enable() before this | ||
| Line 293: | Line 293: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''RawSampleInt''' | ||
|- | |- | ||
| colspan="2" | Background call to read the ADC at full bit depth Call Enable() first | | colspan="2" | Background call to read the ADC at full bit depth Call Enable() first | ||
| Line 307: | Line 307: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetChannel''' | ||
|- | |- | ||
| colspan="2" | Sets the channel ID for the component | | colspan="2" | Sets the channel ID for the component | ||
| Line 326: | Line 326: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetProperties''' | ||
|- | |- | ||
| colspan="2" | Set the VRef options and voltage, ConvSpeed and AcqTime for the ADC component. | | colspan="2" | Set the VRef options and voltage, ConvSpeed and AcqTime for the ADC component. | ||
| Line 361: | Line 361: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''Properties''' | ||
|- | |- | ||
|- | |- | ||
Revision as of 14:23, 13 July 2026
| Author | Matrix Ltd |
| Version | 1.3 |
| Category | Analog Input |
ADC Template 2D component
Base ADC component with no graphical interface. Contains all of the embedded side component calls to provide an ADC interface suitable for wrapping with a new ADC style component.
Detailed description
No detailed description exists yet for this component
Examples
Macro reference
GetAverageByte
| GetAverageByte | |
| Function call to read the ADC as a byte average sample over time | |
| NumSamples | |
| DelayUs | |
| Number of micro seconds in between taking each sample | |
| Return | |
GetAverageInt
| GetAverageInt | |
| Function call to read the ADC as a full width average sample over time | |
| NumSamples | |
| DelayUs | |
| Number of micro seconds in between taking each sample | |
| Return | |
GetByte
| GetByte | |
| Blocking call to read the ADC as a byte | |
| Return | |
GetInt
| GetInt | |
| Blocking call to read the ADC at full bit depth | |
| Return | |
GetSampleBits
| GetSampleBits | |
| Gets the number of bits per sample | |
| Return | |
GetSpeedFilter
| GetSpeedFilter | |
| Gets the Conversion speed filter string Use in Component.Property.SetFilter() | |
| Return | |
GetString
| GetString | |
| Reads the ADC as a direct voltage and returns as a string | |
| Return | |
GetVoltage
| GetVoltage | |
| Reads the ADC as a direct voltage | |
| Return | |
RawAverageByte
RawAverageInt
| RawAverageInt | |
| Background call to read the ADC as a full width average sample over time Call Enable() before this | |
| NumSamples | |
| DelayUs | |
| Return | |
RawDisable
| RawDisable | |
| Disables the previously enabled ADC channel and converts back to digital mode. | |
| Return | |
RawEnable
| RawEnable | |
| Enables and configures the ADC channel to be an analogue input. Only one ADC channel can be enabled at a time. Any RAW functions will reference the last enabled channel only. | |
| Return | |
RawSampleByte
| RawSampleByte | |
| Background call to read the ADC as a byte Call Enable() before this | |
| Return | |
RawSampleInt
| RawSampleInt | |
| Background call to read the ADC at full bit depth Call Enable() first | |
| Return | |
SetChannel
| SetChannel | |
| Sets the channel ID for the component | |
| ChannelId | |
| Chaannel starting at 0, -1 is unconnected | |
| Return | |
SetProperties
Property reference
Component Source Code
Please click here to download the component source project: FC_Comp_Source_adc_Base_2dgdi.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_adc_Base_2dgdi.fcfx