Jump to content

Component: K8055D (Third Party)

From Flowcode Help
Revision as of 11:50, 3 February 2023 by Wiki bot (talk | contribs)
Author Matrix Ltd
Version 2.3
Category Third Party


K8055D component

Support for the Velleman K8055 USB input/output board. Allows Flowcode to communicate with up to four K8055 boards, or to simulate them with interactive on-screen controls. All digital and analog I/O functions are supported.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_K8055D.fcsx

Please click here to view the component source code (Beta): FC_Comp_Source_K8055D.fcsx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples



Macro reference

GetCount

GetCount
Read the value of the chosen counter for the currently selected board. 
- INT Counter
The counter to read (1 or 2) 
- UINT Return


GetAnalogIn

GetAnalogIn
Read analog input 1 or 2 
- INT Input
Which input to read (1 ro 2) 
- INT Return


SetAnalogOut

SetAnalogOut
Sets the chosen analog output to the given value (0-255) 
- BYTE Output
Which output to set the value for (1 ro 2) 
- BYTE Value
Value to set (0-255) 
- VOID Return


SetDigitalOut

SetDigitalOut
Sets the state of the output given by the output index (1 to 8) 
- BYTE Out
Number of the output to set the value for 
- BOOL Value
 
- VOID Return


GetDigitalByte

GetDigitalByte
Read all five inputs at once, returning them as a bit pattern in a byte. The upper three bits will always be zero. 
- INT Return


ResetCount

ResetCount
Resets the chosen counter of the currently selected board. 
- INT Counter
Which counter to reset (1 or 2) 
- VOID Return


GetDevices

GetDevices
Returns a value representing the available devices. Device is a binary value where bit(N) set = device at address (N) is connected. 
- INT Return


Select

Select
Selects the board address to send to and receive data from. Echos the address if the selection is valid. Returns -1 if there is no device available at that address. 
- INT Address
The address off the board to be selected (0...3). 
- INT Return


SetDigitalByte

SetDigitalByte
Sets all eight digital outputs according to the individual bits of the Value parameter. 
- BYTE Value
Value to send to the selected board. 
- VOID Return


GetDigitalIn

GetDigitalIn
Read the individual input at the given index (1..5) 
- INT Input
Which input to read (1 to 5) 
- INT Return


SetCountDebounce

SetCountDebounce
Set the amount of time allowed for switches to settle before being counted as a new event to count. 
- INT Counter
Which counter to make a setting for (1 or 2) 
- INT DebounceTime
Settling time for switch debouncing in milliseconds 
- VOID Return



Property reference

Properties
Simulation
Addr 0
Use software simulation to emulate a board connected at address 0. 
Addr 1
Use software simulation to emulate a board connected at address 1. 
Addr 2
Use software simulation to emulate a board connected at address 2. 
Addr 3
Use software simulation to emulate a board connected at address 3. 
Hardware
Scan
Request a scan of the currently connected hardware to detect what Velleman boards are connected and at what addresses. Where hardware is not detected at an addess, a System Panel simulation will be used instead where one has been requested in the properties.