Bot test

From Flowcode Help
Revision as of 15:08, 10 August 2021 by DavidA (talk | contribs)
Jump to navigationJump to search

Macro References

Fc9-comp-macro.png StringRead
Returns the ASCII value of character idx of the Response string.
Fc9-u8-icon.png - Byte idx
Needs to be a equal to or less than the string length of the response in order to retrieve a valid character.
Fc9-u8-icon.png - Byte Return


Fc9-comp-macro.png SendScript
Sends Script idx

Note that the general property Number of Scripts needs to be set so that it allows the scripts to be accessed and sent. Returns 0 for success and 1 for error

Fc9-u8-icon.png - Byte idx
Refers to the Script page to send (1-4).
Fc9-u8-icon.png - Byte Return


Fc9-comp-macro.png SendCommand
Sends the command buffer.

Returns 1 for success in sending the command. Returns 0 for errors.

Fc9-u8-icon.png - Byte ExpectEcho
Remote module automatically echos back data: 1 = On (Expect echo), 0 = off
Fc9-u8-icon.png - Byte SendCR
Automatically adds \n to the end of the command data: 1 = append CR, 0 = no CR.
Fc9-u8-icon.png - Byte Return


Fc9-comp-macro.png CreateCommandString
Assigns a string of characters to the Command buffer.

Returns 1 for success in adding the characters to the buffer. Returns 0 for errors, including Buffer overflow.

Fc9-string-icon.png - String Data
This parameter may be returned back to the caller
Fc9-u8-icon.png - Byte Return

Component Property Reference

Fc9-prop-icon.png Properties
Returns the ASCII value of character idx of the Response string.
Fc9-u8-icon.png - Byte idx
Needs to be a equal to or less than the string length of the response in order to retrieve a valid character.
Fc9-u8-icon.png - Byte Return