Component: Modbus Slave (SCADA) (Comms: System)

From Flowcode Help
Revision as of 16:22, 7 January 2022 by Wiki bot (talk | contribs)
Author Matrix TSL
Version 1.0
Category Comms: System


Modbus Slave (SCADA) component

Modbus component for creating Modbus compatible slave hardware via RS232 or RS485.

Component Pack

SCADA

Detailed description

No detailed description exists yet for this component

Examples

No additional examples


Downloadable macro reference

ReadHoldingRegister
Reads the value of a single holding register. 
- UINT Address
Coil Address 
- UINT Return


SetCoil
Sets the state of a single digital coil. 
- UINT Address
Coil Address 
- BYTE State
0=off, 1=on 
- VOID Return


SetDigitalInput
Sets the state of a single digital input. 
- UINT Address
Coil Address 
- BYTE State
0=off, 1=on 
- VOID Return


SetSlaveAddress
Allows the slave address to be overridden from the default slave address specified in the component property. The number of bytes used for the address is fixed by the Slave ID Bytes property to save on RAM usage. 
- UINT SlaveAddress
 
- VOID Return


ChangeFrameType
Default frame type is the type set in the component properties. 
- BYTE Type
0 = Modbus RTU / 1 = Modbus ASCII 
- VOID Return


ReadCoils
Reads the state of up to eight digital coils. Can pack a max of 8-bits together in a single operation 
- UINT StartAddress
Coil Address Range 0 to (NumCoils - 1) 
- BYTE AddressCount
Range 1-8 
- BYTE Return


SetHoldingRegister
Sets the state of a single holding register. 
- UINT Address
Coil Address 
- UINT Value
Analogue Value range 0 - 65535 
- VOID Return


ReadAnalogInput
Reads the value of a single analogue input. 
- UINT Address
Coil Address 
- UINT Return


CheckForIncoming
Checks for an incoming message and if the data address is within range then also automatically replies with the correct reply. Returns 0 if no comms received, 1 for a succesful transaction, 255 for an error. 
- BYTE Return


ReadDigitalInputs
Reads the state of up to eight digital inputs. Can pack a max of 8-bits together in a single operation 
- UINT StartAddress
Coil Address Range 0 to (NumCoils - 1) 
- BYTE AddressCount
Range 1-8 
- BYTE Return


GetLastIncoming
Gets a value from the last incoming command. Index 0 = 0 Read / 1 Write Index 1 = 0 Coils / 1 DigInput / 2 AnInput / 3 Register Index 2 = Address Index 3 = Number 
- UINT Return


SetAnalogInput
Sets the state of a single analogue input. 
- UINT Address
Coil Address 
- UINT Value
Analogue Value range 0 - 65535 
- VOID Return


Initialise
Starts up the UART to allow communications and initialises the states of the various Modbus Coils, Inputs and Registers to 0. 
- VOID Return



Property reference

Properties
Frame Type
Switches between RTU and ASCII forms of Modbus 
Receive Buffer Size
Maximum number of bytes the receive buffer can hold 
Receive Timeout
Length in milliseconds to wait for additional bytes to be received when checking for incoming messages. 
Slave ID Bytes
Number of bytes used when passing a slave ID, usually 1 but sometimes 2 
Slave Address
 
Reply Delay
Delay in micro seconds to wait before transmitting a reply 
Maintain Stats
Controls if the last command from the master is logged allowing for easier value updates. No - Do not log commands Yes - Commands are logged and available via the GetLastIncoming macro 
Label
A text label to appear on the Modbus panel object. 
Console Data
Selects if the console data is automatically generated or not 
Console Columns
Number of characters that can be displayed on a single line of the console. 
Data Source
Simulation data source used to allow the component to connect to various remote devices Nothing - Simulation data is ignored COM port - Routes the communication data to and from a physical or virtual COM port Injector - Routes the communication data via a data injector component on the Panel. 
COM Port
Lists all the current available COM port hardware on your PC. 
Refresh Ports
 
Baud Rate
COM port data rate in bits per second 
Starting Address
Start address of the Modbus coils. Referenced from 0. For example Slave 1 might have 100 coils addressed 0-99 Start Address = 0 Slave 2 might have 100 coils addressed 100-199 Start Address = 100 
Number of Addresses
Specifies how many Coils are available on the slave. Each address consumes a single bit of RAM, 8 Addresses are packed together into a single RAM Byte. 
Starting Address
Start address of the Modbus digital inputs. Referenced from 0. For example Slave 1 might have 100 inputs addressed 0-99 Start Address = 0 Slave 2 might have 100 inputs addressed 100-199 Start Address = 100 
Number of Addresses
Specifies how many Digital Inputs are available on the slave. Each address consumes a single bit of RAM, 8 Addresses are packed together into a single RAM Byte. 
Starting Address
Start address of the Modbus analogue inputs. Referenced from 0. For example Slave 1 might have 100 inputs addressed 0-99 Start Address = 0 Slave 2 might have 100 inputs addressed 100-199 Start Address = 100 
Number of Addresses
Specifies how many 16-bit analogue inputs are available on the slave. Each address consumes two RAM Bytes. 
Starting Address
Start address of the Modbus registers. Referenced from 0. For example Slave 1 might have 100 registers addressed 0-99 Start Address = 0 Slave 2 might have 100 registers addressed 100-199 Start Address = 100 
Number of Addresses
Specifies how many 16-bit holding registers are available on the slave. Each address consumes two RAM Bytes. 
Connections