Component: K8055D (Third Party)
From Flowcode Help
Jump to navigationJump to search| Author | Matrix Ltd |
| Version | 2.3 |
| Category | Third Party |
Contents
K8055D component
Support for the Velleman K8055 USB input/output board. Allows Flowcode to communicate with up to four K8055 boards, or to simulate them with interactive on-screen controls. All digital and analog I/O functions are supported.
Component Source Code
Please click here to view the component source code (Beta): FC_Comp_Source_K8055D.fcsx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
| GetCount | |
| Read the value of the chosen counter for the currently selected board. | |
| Counter | |
| The counter to read (1 or 2) | |
| Return | |
| GetAnalogIn | |
| Read analog input 1 or 2 | |
| Input | |
| Which input to read (1 ro 2) | |
| Return | |
| SetAnalogOut | |
| Sets the chosen analog output to the given value (0-255) | |
| Output | |
| Which output to set the value for (1 ro 2) | |
| Value | |
| Value to set (0-255) | |
| Return | |
| SetDigitalOut | |
| Sets the state of the output given by the output index (1 to 8) | |
| Out | |
| Number of the output to set the value for | |
| Value | |
| Return | |
| GetDigitalByte | |
| Read all five inputs at once, returning them as a bit pattern in a byte. The upper three bits will always be zero. | |
| Return | |
| ResetCount | |
| Resets the chosen counter of the currently selected board. | |
| Counter | |
| Which counter to reset (1 or 2) | |
| Return | |
| GetDevices | |
| Returns a value representing the available devices. Device is a binary value where bit(N) set = device at address (N) is connected. | |
| Return | |
| SetDigitalByte | |
| Sets all eight digital outputs according to the individual bits of the Value parameter. | |
| Value | |
| Value to send to the selected board. | |
| Return | |
| GetDigitalIn | |
| Read the individual input at the given index (1..5) | |
| Input | |
| Which input to read (1 to 5) | |
| Return | |
Property reference
==Macro reference==
| GetCount | |
| Read the value of the chosen counter for the currently selected board. | |
| Counter | |
| The counter to read (1 or 2) | |
| Return | |
| GetAnalogIn | |
| Read analog input 1 or 2 | |
| Input | |
| Which input to read (1 ro 2) | |
| Return | |
| SetAnalogOut | |
| Sets the chosen analog output to the given value (0-255) | |
| Output | |
| Which output to set the value for (1 ro 2) | |
| Value | |
| Value to set (0-255) | |
| Return | |
| SetDigitalOut | |
| Sets the state of the output given by the output index (1 to 8) | |
| Out | |
| Number of the output to set the value for | |
| Value | |
| Return | |
| GetDigitalByte | |
| Read all five inputs at once, returning them as a bit pattern in a byte. The upper three bits will always be zero. | |
| Return | |
| ResetCount | |
| Resets the chosen counter of the currently selected board. | |
| Counter | |
| Which counter to reset (1 or 2) | |
| Return | |
| GetDevices | |
| Returns a value representing the available devices. Device is a binary value where bit(N) set = device at address (N) is connected. | |
| Return | |
| SetDigitalByte | |
| Sets all eight digital outputs according to the individual bits of the Value parameter. | |
| Value | |
| Value to send to the selected board. | |
| Return | |
| GetDigitalIn | |
| Read the individual input at the given index (1..5) | |
| Input | |
| Which input to read (1 to 5) | |
| Return | |