Revision as of 14:11, 20 January 2023

Author Matrix Ltd
Version 1.0
Category Test Injectors


Injector (File) component

Comms data injector to allow data to be streamed to and from a file during simulation. The component will read data from the incoming file and write data to the outgoing file.

Component Source Code

Please click here for the component source code: FC_Comp_Source_InjectorFile.fcfx

Detailed description

No detailed description exists yet for this component

Examples

Example to log the bytes sent via the UART RS232 component to a file as comma separated decimal numbers. FC6 Icon.png LogToFile Contents of the file in the Flowcode project directory after running the simulation.

FileWrite.jpg

Macro reference

Fc9-comp-macro.png SPITransferTrans
Transfer an array of bytes using the SPI bus 
Fc9-u8-icon.png - BYTE Channel
Channel Index: Range 0 - SPI Bus Count - 1 
Fc9-u16-icon.png - UINT Count
Number of bytes to send and receive 
Fc9-u8-icon.png - BYTE DataOut
Outgoing data 
Fc9-u8-icon.png - BYTE DataIn
Incoming data 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png UARTBaud
 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u8-icon.png - BYTE Rate
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png UARTCheckRX
 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png UARTInitialise
 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png SPITransfer
Transfer a byte using the SPI bus 
Fc9-u8-icon.png - BYTE Channel
Channel Index: Range 0 - SPI Bus Count - 1 
Fc9-u8-icon.png - BYTE DataOut
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png SPIPrescaler
Modify the speed of the SPI bus 
Fc9-u8-icon.png - BYTE Channel
Channel Index: Range 0 - SPI Bus Count - 1 
Fc9-u8-icon.png - BYTE Prescaler
Range: 0-2 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png UARTReceive
 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u8-icon.png - BYTE Return


Fc9-comp-macro.png SPIInitialise
Initialsie the SPI module ready for communications 
Fc9-u8-icon.png - BYTE Channel
Channel Index: Range 0 - SPI Bus Count - 1 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png UARTSend
 
Fc9-u8-icon.png - BYTE Channel
 
Fc9-u8-icon.png - BYTE Data
 
Fc9-void-icon.png - VOID Return



Property reference

Fc9-prop-icon.png Properties
Fc9-type-7-icon.png Show Console
 
Fc9-conn-icon.png Incoming File Settings (Rx)
Fc9-type-13-icon.png Incoming File
File to stream incoming data from. File -> Communications component. 
Fc9-type-16-icon.png Parse Mode
Specifies the way we read in the data from the file. Detailed Byte : "z - 122 - 0x7a" Raw : "z" CSV Decimal : "122, " CSV Hex : "0x7a, " 
Fc9-type-16-icon.png Display Mode
Specifies the way we show the data on the console. Detailed Byte : "z - 122 - 0x7a" Raw : "z" CSV Decimal : "122, " CSV Hex : "0x7a, " 
Fc9-type-21-icon.png Values Per Line
Number of values to display on a single line of the data console. 0 = Infinite number of characters 
Fc9-type-7-icon.png Skip Timestamp
A file populated with data from an injector may have a timestamp built in which we may not want to receive. Yes: Skip first 22 characters of each line of data so we don't receive any of the timestamp info. No: Read data normally. 
Fc9-conn-icon.png Outgoing File Settings (Tx)
Fc9-type-13-icon.png Outgoing File
File to store outgoing data. Communications component -> File 
Fc9-type-7-icon.png Clear On Init
No - Append to the end of the file. Yes - Empty file on initialise and start from the beginning of the file. 
Fc9-type-16-icon.png Data Mode
Specifies how the data is represented in the outgoing file. Detailed Byte : "z - 122 - 0x7a" Raw : "z" CSV Decimal : "122, " CSV Hex : "0x7a, " 
Fc9-type-21-icon.png Values Per Line
Number of values to display on a single line, applies to the file and data console. 0 = Infinite number of characters 
Fc9-type-7-icon.png Append Timestamp
Appends a timestamp to the beginning of every line relating to the time the first byte in the line was received. Based on the PC system time. Timestamp in the format "YY/MM/DD - HH:MM:SS - "